The Circuit Breaker, cataloged under National Stock Number 5925-01-674-4490, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 15 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-674-4490 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 4 UNTHREADED HOLE(S) |
| Actuator Position Designation | AT EACH POLE |
| Frequency in Hertz | 60.0 ALL LOCATIONS |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
| Body Height | 2.969 INCHES NOMINAL IN |
| Pole Quantity | 3 |
| Maximum Continuous Load Current Rating Per Pole | 200.0 AMPERES AC ALL LOCATIONS |
| Manual Actuator Type and Quantity | 3 TOGGLE |
| Actuator Function | TRIP-RESET |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 04-40158 | 7/2 Vendor item drawing reference Department of Defense Project Manager-Mobile Electric Power |
| JAE-3-32771-200 | 3/2 Design control — primary reference U.S. Government activity |
| JAE-3-32771-200 | 5/2 Secondary reference U.S. Government activity |
NSN 5925-01-674-4490 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-674-4490: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S). 15 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.