PartsTable TECHNICAL DATA SHEET
NSN 5925-01-672-5083Government record, cited

Circuit Breaker5925-01-672-5083

NSN 5925-01-672-5083 · NIIN 016725083
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-672-5083 · 5925016725083 · NIIN 016725083 · 01-672-5083 · FSC 5925 Circuit Breakers · 29-2793567 · 29-2793567-32 · LELK1-33195-45-V
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Operating Voltage Type and Rating Per Pole in Volts: 80.0 DC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 2 THREADED HOLE(S)
  • Body Style: SINGLE POLE TYPE
  • Circuit Protection Type: OVERCURRENT ALL LOCATIONS
  • Pole Quantity: 1
  • Maximum Continuous Load Current Rating Per Pole: 100.0 AMPERES DC ALL LOCATIONS
Identification
  • NSN: 5925-01-672-5083
  • NIIN: 016725083
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-672-5083, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 14 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-672-5083
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Operating Voltage Type and Rating Per Pole in Volts80.0 DC ALL LOCATIONS
Mounting Facility Type and Quantity2 THREADED HOLE(S)
Body StyleSINGLE POLE TYPE
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Pole Quantity1
Maximum Continuous Load Current Rating Per Pole100.0 AMPERES DC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Nominal Thread Size0.1875 INCHES IN
Trip Delay Time in Seconds Per Rated Continuous Current100.0 NOMINAL AT 100 PCT ALL LOCATIONS
MaterialPLASTIC CASE
Terminal Type and Quantity2 THREADED STUD
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC)
Trip Release MethodTHERMAL OVERLOAD ALL LOCATIONS
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5925-01-718-6469IELHK11-33195-69-V POSSIBLE MATCH
CIRCUIT BREAKER
Possible match (shared part number)Sensata Technologies Maryland, Inc
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
29-2793567 D/9 Drawing number reference only
General Dynamics Mission Systems, Inc.
29-2793567-32 7/2 Vendor item drawing reference
General Dynamics Mission Systems, Inc.
LELK1-33195-45-V 3/2 Design control — primary reference
U.S. Government activity
Related Parts
5925-01-718-6469POSSIBLE MATCH
CIRCUIT BREAKER
IELHK11-33195-69-V

Frequently Asked Questions

What is NSN 5925-01-672-5083?

NSN 5925-01-672-5083 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What NSN replaces 5925-01-672-5083?

1 possible match (shared part number, not a government interchangeability claim): 5925-01-718-6469. Verify interchangeability with system specifications before substitution.

What are the specifications of 5925-01-672-5083?

Key specifications for 5925-01-672-5083: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 80.0 DC ALL LOCATIONS; Mounting Facility Type and Quantity: 2 THREADED HOLE(S); Overall Height: 2.490 INCHES NOMINAL IN. 14 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-672-5083 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com