The Circuit Breaker, cataloged under National Stock Number 5925-01-666-4809, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Honeywell International Inc Dba Honeywell International. Government technical data includes 7 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-666-4809 |
| Primary Part Number | GCP-32AI5A |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Honeywell International Inc Dba Honeywell International |
| Status | ACTIVE |
| Operating Voltage Type and Rating Per Pole in Volts | 60.0 DC ALL LOCATIONS |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Pole Quantity | 1 |
| Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES DC ALL LOCATIONS |
| Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.02 NOMINAL AT 100 PCT ALL LOCATIONS |
| Terminal Type and Quantity | 2 SCREW |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| GCP-32AI5A PRIMARY | Honeywell International Inc Dba Honeywell International (USA) |
NSN 5925-01-666-4809 is a Circuit Breaker, manufactured by Honeywell International Inc Dba Honeywell International, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-666-4809 has 1 manufacturer part number on file: GCP-32AI5A (Honeywell International Inc Dba Honeywell International).
Key specifications for GCP-32AI5A: Operating Voltage Type and Rating Per Pole in Volts: 60.0 DC ALL LOCATIONS; Circuit Protection Type: OVERCURRENT ALL LOCATIONS; Pole Quantity: 1; Maximum Continuous Load Current Rating Per Pole: 30.0 AMPERES DC ALL LOCATIONS. 7 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.