The Circuit Breaker, cataloged under National Stock Number 5925-01-649-3392, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 27 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-649-3392 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Operating Voltage Type and Rating Per Pole in Volts | 125.0 AC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 2 THREADED STUD(S) |
| Frequency in Hertz | 60 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 0.750 INCHES MAXIMUM IN |
| Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 1.44 INCHES MAXIMUM IN |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 1.515 INCHES MAXIMUM IN |
| Pole Quantity | 2 |
| Mounting Surface to Terminal End Distance | 1.859 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Nominal Thread Size | 0.25 INCHES IN |
| Body Length | 2.490 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 60.0 MAXIMUM AT 150 PCT ALL LOCATIONS |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 0.750 INCHES MAXIMUM IN |
| Inclosure Protection Type for Which Designed | SALT SPRAY PROOF AND MOISTURE RESISTANT |
| Thread Quantity Per Inch | 20 |
| Material | PLASTIC CASE |
| Terminal Type and Quantity | 2 THREADED STUD |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) |
| Boss Height | 0.140 INCHES MAXIMUM IN |
| Trip Release Method | MAGNETIC ALL LOCATIONS |
| Auxiliary Switch Function and Quantity | 1 CONTROL |
| Center to Center Distance Between Terminals Parallel to Length | 1.940 INCHES MAXIMUM IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| LELK11-1REC5-62-20.0-K-01 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-649-3392 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-649-3392: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 125.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 2 THREADED STUD(S); Frequency in Hertz: 60 ALL LOCATIONS. 27 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.