PartsTable TECHNICAL DATA SHEET
NSN 5925-01-649-3375Government record, cited

Circuit Breaker5925-01-649-3375

NSN 5925-01-649-3375 · NIIN 016493375
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-649-3375 · 5925016493375 · NIIN 016493375 · 01-649-3375 · FSC 5925 Circuit Breakers
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Operating Voltage Type and Rating Per Pole in Volts: 125.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 2 THREADED STUD(S)
  • Frequency in Hertz: 60 ALL LOCATIONS
  • Center to Center Distance Between Terminals Parallel to Width: 0.750 INCHES MAXIMUM IN
  • Body Style: MULTIPOLE-SINGLE ACTUATOR TYPE
  • Distance Between Centerlines of Mounting Facilities Parallel to Body Length: 1.44 INCHES MAXIMUM IN
Identification
  • NSN: 5925-01-649-3375
  • NIIN: 016493375
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-649-3375, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 27 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-649-3375
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Operating Voltage Type and Rating Per Pole in Volts125.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity2 THREADED STUD(S)
Frequency in Hertz60 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.750 INCHES MAXIMUM IN
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Distance Between Centerlines of Mounting Facilities Parallel to Body Length1.44 INCHES MAXIMUM IN
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width1.515 INCHES MAXIMUM IN
Pole Quantity2
Mounting Surface to Terminal End Distance1.859 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole10.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Nominal Thread Size0.25 INCHES IN
Body Length2.490 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current7.0 MAXIMUM AT 150 PCT ALL LOCATIONS
Distance Between Centerlines of Mounting Facilities Parallel to Body Width0.750 INCHES MAXIMUM IN
Inclosure Protection Type for Which DesignedSALT SPRAY PROOF AND MOISTURE RESISTANT
Thread Quantity Per Inch20
MaterialPLASTIC CASE
Terminal Type and Quantity2 THREADED STUD
Main Contact Tripping Mechanism TypeTRIP FREE
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC)
Boss Height0.140 INCHES MAXIMUM IN
Trip Release MethodMAGNETIC ALL LOCATIONS
Auxiliary Switch Function and Quantity1 CONTROL
Center to Center Distance Between Terminals Parallel to Length1.940 INCHES MAXIMUM IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
LELK-1REC5-61-10.0-K-01 3/2 Design control — primary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-649-3375?

NSN 5925-01-649-3375 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-649-3375?

Key specifications for 5925-01-649-3375: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 125.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 2 THREADED STUD(S); Frequency in Hertz: 60 ALL LOCATIONS. 27 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-649-3375 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com