The Circuit Breaker, cataloged under National Stock Number 5925-01-615-5105, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 25 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-615-5105 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP W/AUXILIARY LOAD TERMINAL AND REMOTE TRIP FEATURE ALL LOCATIONS |
| Mounting Facility Type and Quantity | 8 THREADED HOLE(S) |
| Actuator Position Designation | BETWEEN POLE TWO AND THREE |
| Thread Tolerance Class | 6-32 INTERNAL |
| Switch Terminal Type | SCREW |
| Body Style | SINGLE POLE TYPE |
| External Actuator Linkage Arrangement | TWO AND THREE LINKED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 1.660 INCHES NOMINAL IN |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 3.015 INCHES NOMINAL IN |
| Pole Quantity | 4 |
| Mounting Surface to Terminal End Distance | 2.075 INCHES NOMINAL IN |
| Maximum Continuous Load Current Rating Per Pole | 0.50 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Body Length | 2.000 INCHES NOMINAL IN |
| Manual Actuator Type and Quantity | 2 TOGGLE |
| Thread Quantity Per Inch | 32 |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 8 SCREW |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Trip Release Method | MAGNETIC ALL LOCATIONS |
| Auxiliary Switch Function and Quantity | 1 CONTROL |
| Center to Center Distance Between Terminals Parallel to Length | 1.530 INCHES NOMINAL IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| H365095-15 | 7/2 Vendor item drawing reference Naval Inventory Control Point Mechanicsburg |
| IEGH6666-1REC4-35593-1-V 2/ | 5/2 Secondary reference U.S. Government activity |
| IEGH6666-1REC4-35593-1-V | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-615-5105 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-615-5105: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP W/AUXILIARY LOAD TERMINAL AND REMOTE TRIP FEATURE ALL LOCATIONS; Mounting Facility Type and Quantity: 8 THREADED HOLE(S); Actuator Position Designation: BETWEEN POLE TWO AND THREE. 25 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.