The Circuit Breaker, cataloged under National Stock Number 5925-01-583-9162, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Carling Technologies, Inc Dba Carlingswitch. Government technical data includes 12 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-583-9162 |
| Primary Part Number | CA2-B2-24-410-422-C |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Carling Technologies, Inc Dba Carlingswitch |
| Status | ACTIVE |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Frequency in Hertz | 50.0 OR 60.0 ALL LOCATIONS |
| Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 1.515 INCHES MAXIMUM IN |
| Pole Quantity | 2 |
| Maximum Continuous Load Current Rating Per Pole | 1.0 AMPERES AC ALL LOCATIONS |
| Body Length | 2.500 INCHES NOMINAL IN |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
| Terminal Type and Quantity | 2 THREADED STUD |
| Trip Release Method | MAGNETIC ALL LOCATIONS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| CA2-B2-24-410-422-C PRIMARY | Carling Technologies, Inc Dba Carlingswitch (USA) |
NSN 5925-01-583-9162 is a Circuit Breaker, manufactured by Carling Technologies, Inc Dba Carlingswitch, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-583-9162 has 1 manufacturer part number on file: CA2-B2-24-410-422-C (Carling Technologies, Inc Dba Carlingswitch).
Key specifications for CA2-B2-24-410-422-C: Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Frequency in Hertz: 50.0 OR 60.0 ALL LOCATIONS; Body Style: MULTIPOLE-SINGLE ACTUATOR TYPE; Circuit Protection Type: OVERCURRENT ALL LOCATIONS. 12 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.