The Circuit Breaker, cataloged under National Stock Number 5925-01-530-1060, is classified within Federal Supply Class 5925 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Eaton Corp Aerospace Commercial Controls Div. Government technical data includes 28 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 3 commercial cross-references from 3 manufacturers, enabling identification through both NSN and commercial part number lookups. 8 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-530-1060 |
| Primary Part Number | AM3R-A3-LC07D-A-50-2 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — No Item Name Available |
| Manufacturer | Eaton Corp Aerospace Commercial Controls Div |
| Status | ACTIVE |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Actuator Function | TRIP-RESET |
| Material | PLASTIC CASE |
| External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
| Manual Actuator Type and Quantity | 3 TOGGLE |
| Nominal Thread Size | 0.138 INCHES IN |
| Reset Method | MANUAL |
| Frequency in Hertz | 60.0 ALL LOCATIONS |
| Actuator Position Designation | AT EACH POLE |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 AC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC ALL LOCATIONS |
| Terminal Type and Quantity | 6 THREADED STUD |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Inclosure Protection Type for Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT |
| Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
| Mounting Surface to Terminal End Distance | 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM IN |
| Center to Center Distance Between Terminals Parallel to Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM IN |
| Pole Quantity | 3 |
| Mounting Facility Type and Quantity | 6 THREADED HOLE(S) |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM IN |
| Fragility Factor | MODERATELY RUGGED |
| Center to Center Distance Between Terminals Parallel to Length | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM IN |
| Thread Quantity Per Inch | 32 |
| Arc Quenching Method | AIR |
| Boss Height | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM IN |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 100614 | General Microwave Corporation Div Kratos Microwave Electronics (USA) |
| AM3R-A3-LC07D-A-50-2 | Eaton Corp Heinemann Products Commercial Controls Div (USA) |
| AM3R-A3-LC07D-A-50-2 PRIMARY | Eaton Corp Aerospace Commercial Controls Div (USA) |
NSN 5925-01-530-1060 is a Circuit Breaker, manufactured by Eaton Corp Aerospace Commercial Controls Div, classified under FSC 5925 (No Item Name Available). Status: active.
NSN 5925-01-530-1060 has 3 cross-referenced part numbers: 100614 (General Microwave Corporation Div Kratos Microwave Electronics), AM3R-A3-LC07D-A-50-2 (Eaton Corp Heinemann Products Commercial Controls Div), AM3R-A3-LC07D-A-50-2 (Eaton Corp Aerospace Commercial Controls Div).
There are 8 known substitutes for 5925-01-530-1060: 2530-00-164-0706, 3455-00-187-2567, 5330-00-863-3529 and 5 more. Verify interchangeability with system specifications before substitution.
Key specifications for AM3R-A3-LC07D-A-50-2: Part Name Assigned by Controlling Agency: CIRCUIT BREAKER; Circuit Protection Type: OVERCURRENT ALL LOCATIONS; Actuator Function: TRIP-RESET; Material: PLASTIC CASE. 30 total characteristics are documented in the Federal Logistics Information System.