The Circuit Breaker, cataloged under National Stock Number 5925-01-530-0895, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 9 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-530-0895 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 AC AND 80.0 DC ALL LOCATIONS |
| Frequency in Hertz | 50.0 OR 60.0 ALL LOCATIONS |
| Pole Quantity | 2 |
| Maximum Continuous Load Current Rating Per Pole | 25.0 AMPERES AC AND 25.0 AMPERES DC ALL LOCATIONS |
| Terminal Type and Quantity | 4 SCREW |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| IUGN-66-1-72-25 | 5/9 Secondary reference U.S. Government activity |
| IUGN--66-1-72-25.0 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-530-0895 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
1 possible match (shared part number, not a government interchangeability claim): 5925-01-531-6418. Verify interchangeability with system specifications before substitution.
Key specifications for 5925-01-530-0895: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC AND 80.0 DC ALL LOCATIONS; Frequency in Hertz: 50.0 OR 60.0 ALL LOCATIONS. 9 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.