The Circuit Breaker, cataloged under National Stock Number 5925-01-524-4718, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 15 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-524-4718 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Internal Trip Release Configuration | SHUNT TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 80.0 DC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 2 THREADED HOLE(S) |
| Switch Terminal Type | TAB W/SCREW |
| Body Style | SINGLE POLE TYPE |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 0.750 INCHES NOMINAL IN |
| Body Height | 2.000 INCHES NOMINAL IN |
| Pole Quantity | 1 |
| Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Body Length | 2.256 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 60.000 MAXIMUM AT 125 PCT AND 30.000 MAXIMUM AT 150 PCT AND 10.000 MAXIMUM AT 200 PCT AND 2.000 MAXIMUM AT 400 PCT AND 1.000 MAXIMUM AT 600 PCT AND 0.500 MAXIMUM AT 800 PCT AND 0.100 MAXIMUM AT 1000 PCT SINGLE LOCATION |
| Trip Release Method | MAGNETIC SINGLE LOCATION |
| Center to Center Distance Between Terminals Parallel to Length | 1.530 INCHES NOMINAL IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| IAGN-1-1-52-30.0 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-524-4718 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-524-4718: Internal Trip Release Configuration: SHUNT TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 80.0 DC SINGLE LOCATION; Mounting Facility Type and Quantity: 2 THREADED HOLE(S); Switch Terminal Type: TAB W/SCREW. 15 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.