The Circuit Breaker, cataloged under National Stock Number 5925-01-503-6177, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-503-6177 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Bushing Length | 0.240 INCHES NOMINAL IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 125.0 DC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 4 UNTHREADED HOLE(S) |
| Frequency in Hertz | 50.0 OR 60.0 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 0.750 INCHES NOMINAL IN |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 135.0 ALL LOCATIONS |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 1.660 INCHES NOMINAL IN |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 1.515 INCHES MAXIMUM IN |
| Unthreaded Mounting Hole Diameter | 0.156 INCHES NOMINAL IN |
| Trip Release Duty Cycle | CONTINUOUS ALL LOCATIONS |
| Pole Quantity | 2 |
| Mounting Surface to Terminal End Distance | 2.075 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES DC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 3000.0 DC ALL LOCATIONS |
| Body Length | 2.000 INCHES NOMINAL IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 1.800 MINIMUM AT 125 PCT AND 100.000 MAXIMUM AT 125 PCT AND 0.006 MINIMUM AT 1000 PCT AND 0.280 MAXIMUM AT 1000 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Inclosure Protection Type for Which Designed | MOISTURE RESISTANT AND SALT SPRAY PROOF |
| Material | MICA CASE |
| Actuator Function | TRIP-RESET |
| Trip Release Ambient Temp Rating | -40.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM ALL LOCATIONS DEGC |
| Terminal Type and Quantity | 4 QUICK DISCONNECT, MALE |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Trip Release Method | MAGNETIC ALL LOCATIONS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| IEG11-1-72-30.0-91-V | C/1 Advisory reference — outside the item-of-supply concept Airpax Co Government Sales Office a Div of North American Philips Corp |
| IEG11-1-72-30.0-91-V | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-503-6177 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-503-6177: Bushing Length: 0.240 INCHES NOMINAL IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 125.0 DC ALL LOCATIONS. 29 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.