PartsTable TECHNICAL DATA SHEET
NSN 5925-01-503-3175Government record, cited

Circuit Breaker5925-01-503-3175

NSN 5925-01-503-3175 · NIIN 015033175
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-503-3175 · 5925015033175 · NIIN 015033175 · 01-503-3175 · FSC 5925 Circuit Breakers
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.625 INCHES NOMINAL IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S)
  • Ultimate Trip Time Per Pole in Seconds: 120.000 MAXIMUM ALL LOCATIONS
  • Frequency in Hertz: 50.0 OR 60.0 ALL LOCATIONS
Identification
  • NSN: 5925-01-503-3175
  • NIIN: 015033175
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-503-3175, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 27 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-503-3175
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.625 INCHES NOMINAL IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts240.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity4 UNTHREADED HOLE(S)
Ultimate Trip Time Per Pole in Seconds120.000 MAXIMUM ALL LOCATIONS
Frequency in Hertz50.0 OR 60.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.750 INCHES NOMINAL IN
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width2.265 INCHES NOMINAL IN
Body Height2.040 INCHES NOMINAL IN
Unthreaded Mounting Hole Diameter0.156 INCHES NOMINAL AND 0.515 INCHES NOMINAL IN
Pole Quantity3
Mounting Surface to Terminal End Distance2.182 INCHES NOMINAL IN
Maximum Continuous Load Current Rating Per Pole15.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps2000.0 AC ALL LOCATIONS
Body Length2.490 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current120.000 MAXIMUM AT 125 PCT ALL LOCATIONS
Manual Actuator Type and Quantity1 TOGGLE
MaterialPLASTIC CASE
Terminal Type and Quantity6 THREADED STUD
Main Contact Tripping Mechanism TypeTRIP FREE
Trip Release MethodMAGNETIC ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Length1.940 INCHES NOMINAL IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
IULNK111-1-62-15.0 3/2 Design control — primary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-503-3175?

NSN 5925-01-503-3175 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-503-3175?

Key specifications for 5925-01-503-3175: Bushing Length: 0.625 INCHES NOMINAL IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS. 27 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-503-3175 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com