PartsTable TECHNICAL DATA SHEET
NSN 5925-01-503-2662Government record, cited

Circuit Breaker5925-01-503-2662

NSN 5925-01-503-2662 · NIIN 015032662 · Part number 205-111-1REC4-61-5-501-AM
2 MB Distribution · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE FAH01
Government record, cited
NSN 5925-01-503-2662 — this item is cataloged by the U.S. Government under National Stock Number 5925-01-503-2662. Manufacturer of record part number: 205-111-1REC4-61-5-501-AM.
Also searched as  5925-01-503-2662 · 5925015032662 · NIIN 015032662 · 01-503-2662 · FSC 5925 Circuit Breakers · CAGE FAH01 · 205-111-1REC4-61-5-501-AM · 91470044 · 205-111-1REC2-61-5-501AM
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Operating Voltage Type and Rating Per Pole in Volts: 277.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 6 UNTHREADED HOLE(S)
  • Frequency in Hertz: 50.0 OR 60.0 ALL LOCATIONS
  • Pole Quantity: 3
  • Maximum Continuous Load Current Rating Per Pole: 0.500 AMPERES AC ALL LOCATIONS
  • Trip Release Characteristic: TIME DELAY ALL LOCATIONS
Identification
  • NSN: 5925-01-503-2662
  • NIIN: 015032662
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 205-111-1REC4-61-5-501-AM
  • Manufacturer: 2 MB Distribution
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-503-2662, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is 2 MB Distribution. Government technical data includes 8 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-503-2662
Primary Part Number205-111-1REC4-61-5-501-AM
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
Manufacturer2 MB Distribution
StatusACTIVE
Reset MethodMANUAL
Operating Voltage Type and Rating Per Pole in Volts277.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity6 UNTHREADED HOLE(S)
Frequency in Hertz50.0 OR 60.0 ALL LOCATIONS
Pole Quantity3
Maximum Continuous Load Current Rating Per Pole0.500 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps5000.0 AC ALL LOCATIONS
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
205-111-1REC4-61-5-501-AM 2 MB Distribution (FRA)
91470044 Thales Sa (FRA)
Reference documents
ReferenceMeaning
205-111-1REC2-61-5-501AM 3/9 Design control — primary reference
U.S. Government activity
205-111-1REC4-61-5-501-AM 3/2 Design control — primary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-503-2662?

NSN 5925-01-503-2662 is a Circuit Breaker, manufactured by 2 MB Distribution, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-01-503-2662?

NSN 5925-01-503-2662 has 2 manufacturer part numbers on file: 205-111-1REC4-61-5-501-AM (2 MB Distribution), 91470044 (Thales Sa).

What are the specifications of 205-111-1REC4-61-5-501-AM?

Key specifications for 205-111-1REC4-61-5-501-AM: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 277.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 6 UNTHREADED HOLE(S); Frequency in Hertz: 50.0 OR 60.0 ALL LOCATIONS. 8 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-503-2662 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com