PartsTable TECHNICAL DATA SHEET
NSN 5925-01-501-8596Government record, cited

Circuit Breaker5925-01-501-8596

NSN 5925-01-501-8596 · NIIN 015018596
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-501-8596 · 5925015018596 · NIIN 015018596 · 01-501-8596 · FSC 5925 Circuit Breakers · 99002A8046 · 99002A8046-24 · IELK11-30372-24 · IELK11-1-63-4.00-01-V
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.140 INCHES NOMINAL IN
  • Reset Method: MANUAL
  • Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 4 THREADED STUD(S)
  • Frequency in Hertz: 60.0 ALL LOCATIONS
  • Center to Center Distance Between Terminals Parallel to Width: 0.750 INCHES NOMINAL IN
  • Body Style: MULTIPOLE-MULTIPLE ACTUATOR TYPE
Identification
  • NSN: 5925-01-501-8596
  • NIIN: 015018596
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-501-8596, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 27 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-501-8596
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.140 INCHES NOMINAL IN
Reset MethodMANUAL
Operating Voltage Type and Rating Per Pole in Volts250.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity4 THREADED STUD(S)
Frequency in Hertz60.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.750 INCHES NOMINAL IN
Body StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.060 INCHES NOMINAL IN
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width2.490 INCHES NOMINAL IN
Pole Quantity2
Mounting Surface to Terminal End Distance2.404 INCHES NOMINAL IN
Maximum Continuous Load Current Rating Per Pole20.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps1000.0 AC ALL LOCATIONS
Nominal Thread Size0.138 INCHES IN
Body Length3.015 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current63.000 NOMINAL AT 125 PCT ALL LOCATIONS
Distance Between Centerlines of Mounting Facilities Parallel to Body Width0.750 INCHES NOMINAL IN
Trip Release Ambient Temp Rating70.0 CELSIUS NOMINAL ALL LOCATIONS DEGC
Terminal Type and Quantity4 THREADED STUD
Main Contact Tripping Mechanism TypeTRIP FREE
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC)
Boss Height1.042 INCHES NOMINAL IN
Trip Release MethodTHERMAL-MAGNETIC ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Length1.940 INCHES NOMINAL IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
99002A8046 D/9 Drawing number reference only
Marine Corps Systems Command Div Marine Corps Systems Command Technical Data Repository Customer Service
99002A8046-24 7/2 Vendor item drawing reference
Marine Corps Systems Command Div Marine Corps Systems Command Technical Data Repository Customer Service
IELK11-30372-24 3/2 Design control — primary reference
U.S. Government activity
IELK11-1-63-4.00-01-V 3/2 Design control — primary reference
U.S. Government activity

Frequently Asked Questions

What is NSN 5925-01-501-8596?

NSN 5925-01-501-8596 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-501-8596?

Key specifications for 5925-01-501-8596: Bushing Length: 0.140 INCHES NOMINAL IN; Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 THREADED STUD(S). 27 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-501-8596 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com