The Circuit Breaker, cataloged under National Stock Number 5925-01-483-0111, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 28 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-483-0111 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES/RELAY TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 AC ALL LOCATIONS |
| Ultimate Trip Time Per Pole in Seconds | 0.700 MINIMUM AND 12.000 MAXIMUM ALL LOCATIONS |
| Switch Terminal Type | QUICK DISCONNECT, MALE |
| Frequency in Hertz | 50.0 OR 60.0 ALL LOCATIONS |
| Body Style | SINGLE POLE TYPE |
| Switch Voltage Rating and Type in Volts | 125.0 AC |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| Switch Location and Position Designation | INTERNAL AT POLE ONE |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 0.750 INCHES NOMINAL IN |
| Trip Release Duty Cycle | CONTINUOUS ALL LOCATIONS |
| Pole Quantity | 1 |
| Maximum Continuous Load Current Rating Per Pole | 15.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 2000.0 AC ALL LOCATIONS |
| Body Length | 2.000 INCHES NOMINAL IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.700 MINIMUM AT 125 PCT AND 12.000 MAXIMUM AT 125 PCT AND 0.350 MINIMUM AT 150 PCT AND 7.000 MAXIMUM AT 150 PCT AND 0.130 MINIMUM AT 200 PCT AND 3.000 MAXIMUM AT 200 PCT AND 0.030 MINIMUM AT 400 PCT AND 1.000 MAXIMUM AT 400 PCT AND 0.015 MINIMUM AT 600 PCT AND 0.300 MAXIMUM AT 600 PCT AND 0.010 MINIMUM AT 800 PCT AND 0.150 MAXIMUM AT 800 PCT AND 0.008 MINIMUM AT 1000 PCT AND 0.100 MAXIMUM AT 1000 PCT ALL LOCATIONS |
| Switch Current Rating and Type in Amps | 1.0 AC |
| Inclosure Protection Type for Which Designed | CORROSION RESISTANT AND MOISTURE RESISTANT AND SALT WATER RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
| Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
| Auxiliary Trip Coil Voltage Type and Rating in Volts | 125.0 AC NOMINAL ALL LOCATIONS |
| Terminal Type and Quantity | 2 SCREW |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
| Auxiliary Switch Function and Quantity | 1 CONTROL |
| Center to Center Distance Between Terminals Parallel to Length | 1.530 INCHES NOMINAL IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| IEG6-1REC4-61-15.0-21-V | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-483-0111 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-483-0111: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES/RELAY TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC ALL LOCATIONS; Ultimate Trip Time Per Pole in Seconds: 0.700 MINIMUM AND 12.000 MAXIMUM ALL LOCATIONS. 28 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.