The Circuit Breaker, cataloged under National Stock Number 5925-01-482-9015, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Carling Technologies, Inc Dba Carlingswitch. Government technical data includes 22 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-482-9015 |
| Primary Part Number | EA2-B0-24-625-2DA-DC |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Carling Technologies, Inc Dba Carlingswitch |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC ALL LOCATIONS |
| Frequency in Hertz | 50.0 OR 60.0 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 1.026 INCHES NOMINAL IN |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 150.0 ALL LOCATIONS |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.750 INCHES NOMINAL IN |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 2.114 INCHES NOMINAL IN |
| Body Height | 2.610 INCHES NOMINAL IN |
| Pole Quantity | 2 |
| Maximum Continuous Load Current Rating Per Pole | 100.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 5000.0 AC ALL LOCATIONS |
| Body Length | 5.125 INCHES NOMINAL IN |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 1.026 INCHES NOMINAL IN |
| Material | PLASTIC CASE |
| Terminal Type and Quantity | 2 THREADED STUD |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Length | 3.550 INCHES NOMINAL IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| EA2-B0-24-625-2DA-DC PRIMARY | Carling Technologies, Inc Dba Carlingswitch (USA) |
| 60002-014 | Curtiss-Wright Flow Control Service, Llc Dba Engineered Arresting Systems - Esco Div Cw Flow Control Svc Llc Dba (USA) |
NSN 5925-01-482-9015 is a Circuit Breaker, manufactured by Carling Technologies, Inc Dba Carlingswitch, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-482-9015 has 2 manufacturer part numbers on file: EA2-B0-24-625-2DA-DC (Carling Technologies, Inc Dba Carlingswitch), 60002-014 (Curtiss-Wright Flow Control Service, Llc Dba Engineered Arresting Systems - Esco Div Cw Flow Control Svc Llc Dba).
Key specifications for EA2-B0-24-625-2DA-DC: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS; Frequency in Hertz: 50.0 OR 60.0 ALL LOCATIONS. 22 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.