The Circuit Breaker, cataloged under National Stock Number 5925-01-469-5727, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 15 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-469-5727 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Operating Voltage Type and Rating Per Pole in Volts | 50.0 DC SINGLE LOCATION |
| Body Style | SINGLE POLE TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 SINGLE LOCATION |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.062 INCHES NOMINAL IN |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 0.755 INCHES NOMINAL IN |
| Body Height | 2.553 INCHES NOMINAL IN |
| Pole Quantity | 1 |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 2000.0 DC SINGLE LOCATION |
| Body Length | 2.530 INCHES NOMINAL IN |
| Boss Height | 0.140 INCHES NOMINAL IN |
| Trip Release Method | MAGNETIC SINGLE LOCATION |
| Center to Center Distance Between Terminals Parallel to Length | 1.810 INCHES NOMINAL IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| MIL-PRF-55629/1 | 4/1 Identification reference U.S. Government activity |
| MIL-C55629/1 | 5/9 Secondary reference U.S. Government activity |
| M55629/1-422 | 2/2 Government specification standardization U.S. Government activity |
NSN 5925-01-469-5727 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-469-5727: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 50.0 DC SINGLE LOCATION; Body Style: SINGLE POLE TYPE; Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent: 125.0 SINGLE LOCATION. 15 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.