PartsTable TECHNICAL DATA SHEET
NSN 5925-01-468-6257Government record, cited

Circuit Breaker5925-01-468-6257

NSN 5925-01-468-6257 · NIIN 014686257
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-468-6257 · 5925014686257 · NIIN 014686257 · 01-468-6257 · FSC 5925 Circuit Breakers · MIL-C-55629B · M55629/17MPMPMP · MIL-C-55629/17
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: RELAY TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 4 THREADED HOLE(S)
  • Frequency in Hertz: 60.0 ALL LOCATIONS
  • Center to Center Distance Between Terminals Parallel to Width: 0.994 INCHES MINIMUM AND 1.056 INCHES MAXIMUM IN
  • Body Style: MULTIPOLE-SINGLE ACTUATOR TYPE
Identification
  • NSN: 5925-01-468-6257
  • NIIN: 014686257
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-468-6257, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 28 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-468-6257
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationRELAY TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts240.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity4 THREADED HOLE(S)
Frequency in Hertz60.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.994 INCHES MINIMUM AND 1.056 INCHES MAXIMUM IN
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.740 INCHES MINIMUM AND 2.760 INCHES MAXIMUM IN
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width3.098 INCHES MINIMUM AND 3.118 INCHES MAXIMUM IN
Pole Quantity3
Mounting Surface to Terminal End Distance3.460 INCHES MINIMUM AND 3.580 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole60.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps60.0 AC ALL LOCATIONS
Nominal Thread Size0.138 INCHES IN
Body Length5.115 INCHES MINIMUM AND 5.135 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current13.000 MINIMUM AT 125 PCT AND 90.000 MAXIMUM AT 150 PCT ALL LOCATIONS
Distance Between Centerlines of Mounting Facilities Parallel to Body Width2.042 INCHES MINIMUM AND 2.062 INCHES MAXIMUM IN
MaterialPLASTIC CASE
Trip Release Ambient Temp Rating40.0 CELSIUS NOMINAL ALL LOCATIONS DEGC
Terminal Type and Quantity6 SOLDER STUD
Main Contact Tripping Mechanism TypeTRIP FREE
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC)
Boss Height0.210 INCHES MINIMUM AND 0.230 INCHES MAXIMUM IN
Trip Release MethodTHERMAL ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Length3.480 INCHES MINIMUM AND 3.614 INCHES MAXIMUM IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5925-01-497-1625 POSSIBLE MATCH
CIRCUIT BREAKER
Possible match (shared part number)
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MIL-C-55629B 5/9 Secondary reference
U.S. Government activity
M55629/17MPMPMP 2/2 Government specification standardization
U.S. Government activity
MIL-C-55629/17 4/1 Identification reference
U.S. Government activity
Related Parts
5925-01-497-1625POSSIBLE MATCH
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-468-6257?

NSN 5925-01-468-6257 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What NSN replaces 5925-01-468-6257?

1 possible match (shared part number, not a government interchangeability claim): 5925-01-497-1625. Verify interchangeability with system specifications before substitution.

What are the specifications of 5925-01-468-6257?

Key specifications for 5925-01-468-6257: Reset Method: MANUAL; Internal Trip Release Configuration: RELAY TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 THREADED HOLE(S). 28 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-468-6257 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com