PartsTable TECHNICAL DATA SHEET
NSN 5925-01-466-5073Government record, cited

Circuit Breaker5925-01-466-5073

NSN 5925-01-466-5073 · NIIN 014665073
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-466-5073 · 5925014665073 · NIIN 014665073 · 01-466-5073 · FSC 5925 Circuit Breakers · CD3-Z458-46 · 13230E6502-2 · 13230E6502 · 219-3-1-43F-4-9-100
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: ELECTRIC
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 6 THREADED STUD(S)
  • Frequency in Hertz: 400.0 ALL LOCATIONS
  • Unpackaged Unit Weight: 2.000 POUNDS NOMINAL LBS
  • Center to Center Distance Between Terminals Parallel to Width: 1.026 INCHES NOMINAL IN
Identification
  • NSN: 5925-01-466-5073
  • NIIN: 014665073
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-466-5073, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-466-5073
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodELECTRIC
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts240.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity6 THREADED STUD(S)
Frequency in Hertz400.0 ALL LOCATIONS
Unpackaged Unit Weight2.000 POUNDS NOMINAL LBS
Center to Center Distance Between Terminals Parallel to Width1.026 INCHES NOMINAL IN
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent150.0 ALL LOCATIONS
Distance Between Centerlines of Mounting Facilities Parallel to Body Length4.089 INCHES NOMINAL IN
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width3.108 INCHES NOMINAL IN
Body Height3.520 INCHES NOMINAL IN
Trip Release Duty CycleCONTINUOUS ALL LOCATIONS
Pole Quantity3
Maximum Continuous Load Current Rating Per Pole100.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicINSTANTANEOUS ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps150.0 AC ALL LOCATIONS
Nominal Thread Size0.138 INCHES IN
Body Length5.125 INCHES NOMINAL IN
Manual Actuator Type and Quantity3 TOGGLE
Distance Between Centerlines of Mounting Facilities Parallel to Body Width1.360 INCHES NOMINAL IN
MaterialPLASTIC CASE
Terminal Type and Quantity3 TURRET
Reset Actuator Voltage Rating and Type in Volts240.0 AC
Main Contact Tripping Mechanism TypeTRIP FREE
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC)
Boss Height0.220 INCHES NOMINAL IN
Trip Release MethodMAGNETIC ALL LOCATIONS
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
CD3-Z458-46 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
13230E6502-2 3/2 Design control — primary reference
U.S. Government activity
13230E6502 5/9 Secondary reference
U.S. Government activity
219-3-1-43F-4-9-100 5/2 Secondary reference
U.S. Government activity

Frequently Asked Questions

What is NSN 5925-01-466-5073?

NSN 5925-01-466-5073 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-466-5073?

Key specifications for 5925-01-466-5073: Reset Method: ELECTRIC; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 6 THREADED STUD(S). 29 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-466-5073 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com