PartsTable TECHNICAL DATA SHEET
NSN 5925-01-444-5076Government record, cited

Circuit Breaker5925-01-444-5076

NSN 5925-01-444-5076 · NIIN 014445076 · Part number AM2-Z596-1
Heinemann Electric Canada Incdivision of Eaton Corp · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE L3330
Government record, cited
NSN 5925-01-444-5076 — this item is cataloged by the U.S. Government under National Stock Number 5925-01-444-5076. Manufacturer of record part number: AM2-Z596-1.
Also searched as  5925-01-444-5076 · 5925014445076 · NIIN 014445076 · 01-444-5076 · FSC 5925 Circuit Breakers · CAGE L3330 · AM2-Z596-1 · C10010-9
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP FIRST LOCATION
  • Internal Trip Release Configuration: RELAY TRIP SECOND LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 4 CLIP
  • Frequency in Hertz: 60.0 FIRST LOCATION
  • Center to Center Distance Between Terminals Parallel to Width: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM IN
Identification
  • NSN: 5925-01-444-5076
  • NIIN: 014445076
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: AM2-Z596-1
  • Manufacturer: Heinemann Electric Canada Incdivision of Eaton Corp
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-444-5076, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Heinemann Electric Canada Incdivision of Eaton Corp. Government technical data includes 26 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-444-5076
Primary Part NumberAM2-Z596-1
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerHeinemann Electric Canada Incdivision of Eaton Corp
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP FIRST LOCATION
Internal Trip Release ConfigurationRELAY TRIP SECOND LOCATION
Operating Voltage Type and Rating Per Pole in Volts250.0 AC SINGLE LOCATION
Mounting Facility Type and Quantity4 CLIP
Frequency in Hertz60.0 FIRST LOCATION
Center to Center Distance Between Terminals Parallel to Width0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM IN
Body StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM IN
Circuit Protection TypeOVERCURRENT FIRST LOCATION
Body Width1.480 INCHES MINIMUM AND 1.520 INCHES MAXIMUM IN
Pole Quantity2
Mounting Surface to Terminal End Distance2.850 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole15.0 AMPERES DC SINGLE LOCATION
Trip Release CharacteristicINSTANTANEOUS SECOND LOCATION
Trip Release CharacteristicTIME DELAY FIRST LOCATION
Body Length2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current2.000 MAXIMUM AT 200 PCT FIRST LOCATION
Distance Between Centerlines of Mounting Facilities Parallel to Body Width0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM IN
MaterialPLASTIC CASE
Terminal Type and Quantity6 THREADED STUD
Main Contact Tripping Mechanism TypeTRIP FREE
Boss Height0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM IN
Trip Release MethodMAGNETIC ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Length1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
AM2-Z596-1 Heinemann Electric Canada Incdivision of Eaton Corp (CAN)
Reference documents
ReferenceMeaning
AM2-Z596-1 3/9 Design control — primary reference
Eaton Corp Heinemann Products Commercial Controls Div
C10010-9 7/2 Vendor item drawing reference
U.S. Government activity

Frequently Asked Questions

What is NSN 5925-01-444-5076?

NSN 5925-01-444-5076 is a Circuit Breaker, manufactured by Heinemann Electric Canada Incdivision of Eaton Corp, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-01-444-5076?

NSN 5925-01-444-5076 has 1 manufacturer part number on file: AM2-Z596-1 (Heinemann Electric Canada Incdivision of Eaton Corp).

What are the specifications of AM2-Z596-1?

Key specifications for AM2-Z596-1: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP FIRST LOCATION; Internal Trip Release Configuration: RELAY TRIP SECOND LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC SINGLE LOCATION. 26 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-444-5076 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com