The Circuit Breaker, cataloged under National Stock Number 5925-01-441-9569, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-441-9569 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Bushing Length | 0.625 INCHES NOMINAL IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SECOND LOCATION |
| Internal Trip Release Configuration | SERIES TRIP W/AUXILIARY LOAD TERMINAL THIRD LOCATION |
| Internal Trip Release Configuration | SERIES TRIP W/DUAL RATING FIRST LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 115.0 AC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 4 THREADED BUSHING WITH PANEL SEAL |
| Actuator Position Designation | AT POLE TWO |
| Thread Tolerance Class | 2B EXTERNAL |
| Ultimate Trip Time Per Pole in Seconds | 0.500 NOMINAL ALL LOCATIONS |
| Frequency in Hertz | 400.0 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 0.750 INCHES NOMINAL IN |
| Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 150.0 ALL LOCATIONS |
| Switch Location and Position Designation | INTERNAL AT POLE THREE |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 2.265 INCHES NOMINAL IN |
| Trip Release Duty Cycle | CONTINUOUS ALL LOCATIONS |
| Pole Quantity | 3 |
| Mounting Surface to Terminal End Distance | 2.232 INCHES NOMINAL IN |
| Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 2000.0 AC ALL LOCATIONS |
| Nominal Thread Size | 32.000 INCHES IN |
| Body Length | 2.000 INCHES NOMINAL IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.500 NOMINAL AT 150 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Switch Contact Arrangement | DOUBLE POLE, SINGLE THROW, NORMALLY OPEN |
| Auxiliary Trip Coil Voltage Type and Rating in Volts | 10.0 AC NOMINAL THIRD LOCATION |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| APGN266-1REC4-28055-1 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-441-9569 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-441-9569: Bushing Length: 0.625 INCHES NOMINAL IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SECOND LOCATION; Internal Trip Release Configuration: SERIES TRIP W/AUXILIARY LOAD TERMINAL THIRD LOCATION. 29 specifications are documented in the U.S. Government catalog.