Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 6 THREADED HOLE(S)
  • Frequency in Hertz: 400.0 ALL LOCATIONS
  • Center to Center Distance Between Terminals Parallel to Width: 1.026 INCHES NOMINAL IN
  • Body Style: MULTIPOLE-MULTIPLE ACTUATOR TYPE
Identification
  • NSN: 5925-01-441-3841
  • NIIN: 014413841
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-441-3841, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 28 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 6 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-441-3841
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts240.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity6 THREADED HOLE(S)
Frequency in Hertz400.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width1.026 INCHES NOMINAL IN
Body StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.750 INCHES NOMINAL IN
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width3.108 INCHES NOMINAL IN
Pole Quantity3
Mounting Surface to Terminal End Distance3.520 INCHES NOMINAL IN
Maximum Continuous Load Current Rating Per Pole100.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Nominal Thread Size0.138 INCHES IN
Specification/standard Data81349-MIL-C-55629/17 GOVERNMENT SPECIFICATION
Body Length5.125 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current3.800 MINIMUM AT 200 PCT AND 17.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Distance Between Centerlines of Mounting Facilities Parallel to Body Width1.026 INCHES NOMINAL IN
Test Data Document81349-MIL-C-55629 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
MaterialPLASTIC CASE
Terminal Type and Quantity6 THREADED STUD
Main Contact Tripping Mechanism TypeTRIP FREE
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC)
Boss Height0.220 INCHES NOMINAL IN
Trip Release MethodMAGNETIC ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Length3.547 INCHES NOMINAL IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 6
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5925-01-446-1494 POSSIBLE MATCH
CIRCUIT BREAKER
Possible match (shared part number)
5925-01-446-3353 POSSIBLE MATCH
CIRCUIT BREAKER
Possible match (shared part number)
5925-01-468-6257 POSSIBLE MATCH
CIRCUIT BREAKER
Possible match (shared part number)
5925-01-497-1625 POSSIBLE MATCH
CIRCUIT BREAKER
Possible match (shared part number)
5925-01-497-1928 POSSIBLE MATCH
CIRCUIT BREAKER
Possible match (shared part number)
5925-01-497-1930 POSSIBLE MATCH
CIRCUIT BREAKER
Possible match (shared part number)
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
219-3-1REC4-42F-4-9-100-H 3/2 Design control — primary reference
U.S. Government activity
MIL-C-55629/17 5/9 Secondary reference
U.S. Government activity
M55629/17QSQSQS 5/9 Secondary reference
U.S. Government activity
209-3-1REC4-42F-4-9-100-H 5/9 Secondary reference
U.S. Government activity
Related Parts
5925-01-446-1494POSSIBLE MATCH
CIRCUIT BREAKER
5925-01-446-3353POSSIBLE MATCH
CIRCUIT BREAKER
5925-01-468-6257POSSIBLE MATCH
CIRCUIT BREAKER
5925-01-497-1625POSSIBLE MATCH
CIRCUIT BREAKER
5925-01-497-1928POSSIBLE MATCH
CIRCUIT BREAKER
5925-01-497-1930POSSIBLE MATCH
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-441-3841?

NSN 5925-01-441-3841 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What NSN replaces 5925-01-441-3841?

6 possible matches (shared part number, not a government interchangeability claim): 5925-01-446-1494, 5925-01-446-3353, 5925-01-468-6257. Verify interchangeability with system specifications before substitution.

What are the specifications of 5925-01-441-3841?

Key specifications for 5925-01-441-3841: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 6 THREADED HOLE(S). 28 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-441-3841 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com