PartsTable TECHNICAL DATA SHEET
NSN 5925-01-436-2467Government record, cited

Circuit Breaker5925-01-436-2467

NSN 5925-01-436-2467 · NIIN 014362467
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-436-2467 · 5925014362467 · NIIN 014362467 · 01-436-2467 · FSC 5925 Circuit Breakers · MIL-PRF-39019/6 · M39019/06-260 · MIL-C-39019/6
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.380 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC AND 50.0 DC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING WITH PANEL SEAL
  • Frequency in Hertz: 400.0 ALL LOCATIONS
  • Center to Center Distance Between Terminals Parallel to Width: 0.906 INCHES MAXIMUM IN
Identification
  • NSN: 5925-01-436-2467
  • NIIN: 014362467
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-436-2467, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 28 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-436-2467
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.380 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts240.0 AC AND 50.0 DC ALL LOCATIONS
Mounting Facility Type and Quantity1 THREADED BUSHING WITH PANEL SEAL
Frequency in Hertz400.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.906 INCHES MAXIMUM IN
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent135.0 ALL LOCATIONS
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width1.562 INCHES MAXIMUM IN
Pole Quantity3
Mounting Surface to Terminal End Distance1.828 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole1.25 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps1.25 AC AND 1.25 DC ALL LOCATIONS
Nominal Thread Size0.375 INCHES IN
Specification/standard Data81349-MIL-C-39019/6 GOVERNMENT SPECIFICATION
Body Length1.937 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity1 TOGGLE
Test Data Document81349-MIL-C-39019 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
MaterialPLASTIC CASE
Terminal Type and Quantity6 WIRE HOOK
Main Contact Tripping Mechanism TypeTRIP FREE
Thread Series DesignatorUNEF
Trip Release MethodMAGNETIC ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Length0.625 INCHES NOMINAL IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MIL-PRF-39019/6 4/1 Identification reference
U.S. Government activity
M39019/06-260 2/2 Government specification standardization
U.S. Government activity
MIL-C-39019/6 5/9 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-436-2467?

NSN 5925-01-436-2467 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-436-2467?

Key specifications for 5925-01-436-2467: Bushing Length: 0.380 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC AND 50.0 DC ALL LOCATIONS. 28 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-436-2467 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com