PartsTable TECHNICAL DATA SHEET
NSN 5925-01-425-4332Government record, cited

Circuit Breaker5925-01-425-4332

NSN 5925-01-425-4332 · NIIN 014254332 · Part number 29538-1
Smiths Aerospace, Inc., Electronic Systems-Grand Rapids · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 30377
Government record, cited
NSN 5925-01-425-4332 — this item is cataloged by the U.S. Government under National Stock Number 5925-01-425-4332. Manufacturer of record part number: 29538-1.
Also searched as  5925-01-425-4332 · 5925014254332 · NIIN 014254332 · 01-425-4332 · FSC 5925 Circuit Breakers · CAGE 30377 · 29538-1 · JA2S-C3C15-EB-01-D-NU
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP FIRST LOCATION
  • Internal Trip Release Configuration: SERIES TRIP W/REMOTE TRIP FEATURE SECOND LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC FIRST LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 115.0 AC SECOND LOCATION
  • Mounting Facility Type and Quantity: 4 CLIP
  • Actuator Position Designation: AT EACH POLE
Identification
  • NSN: 5925-01-425-4332
  • NIIN: 014254332
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 29538-1
  • Manufacturer: Smiths Aerospace, Inc., Electronic Systems-Grand Rapids
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-425-4332, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Smiths Aerospace, Inc., Electronic Systems-Grand Rapids. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-425-4332
Primary Part Number29538-1
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerSmiths Aerospace, Inc., Electronic Systems-Grand Rapids
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP FIRST LOCATION
Internal Trip Release ConfigurationSERIES TRIP W/REMOTE TRIP FEATURE SECOND LOCATION
Operating Voltage Type and Rating Per Pole in Volts240.0 AC FIRST LOCATION
Operating Voltage Type and Rating Per Pole in Volts115.0 AC SECOND LOCATION
Mounting Facility Type and Quantity4 CLIP
Actuator Position DesignationAT EACH POLE
Frequency in Hertz50.0 OR 60.0 OR 400.0 FIRST LOCATION
Frequency in Hertz50.0 OR 60.0 OR 400.0 SECOND LOCATION
Center to Center Distance Between Terminals Parallel to Width0.750 INCHES NOMINAL IN
Body StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent150.0 FIRST LOCATION
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent150.0 SECOND LOCATION
Distance Between Centerlines of Mounting Facilities Parallel to Body Length1.660 INCHES NOMINAL IN
Circuit Protection TypeOVERCURRENT FIRST LOCATION
Circuit Protection TypeOVERCURRENT SECOND LOCATION
Body Width1.500 INCHES NOMINAL IN
Trip Release Duty CycleCONTINUOUS SECOND LOCATION
Pole Quantity2
Mounting Surface to Terminal End Distance1.950 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole10.0 AMPERES AC AND 10.0 AMPERES DC FIRST LOCATION
Maximum Continuous Load Current Rating Per Pole10.0 AMPERES AC AND 10.0 AMPERES DC SECOND LOCATION
Trip Release CharacteristicTIME DELAY FIRST LOCATION
Trip Release CharacteristicTIME DELAY SECOND LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps2000.0 AC AND 1000.0 DC FIRST LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps2000.0 AC AND 1000.0 DC SECOND LOCATION
Body Length2.000 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current0.400 MINIMUM AT 150 PCT AND 6.000 MAXIMUM AT 150 PCT SECOND LOCATION
Trip Delay Time in Seconds Per Rated Continuous Current6.000 MINIMUM AT 150 PCT AND 70.000 MAXIMUM AT 150 PCT FIRST LOCATION
Manual Actuator Type and Quantity2 TOGGLE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
29538-1 PRIMARY Smiths Aerospace, Inc., Electronic Systems-Grand Rapids (USA)
Reference documents
ReferenceMeaning
JA2S-C3C15-EB-01-D-NU 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-425-4332?

NSN 5925-01-425-4332 is a Circuit Breaker, manufactured by Smiths Aerospace, Inc., Electronic Systems-Grand Rapids, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-01-425-4332?

NSN 5925-01-425-4332 has 1 manufacturer part number on file: 29538-1 (Smiths Aerospace, Inc., Electronic Systems-Grand Rapids).

What are the specifications of 29538-1?

Key specifications for 29538-1: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP FIRST LOCATION; Internal Trip Release Configuration: SERIES TRIP W/REMOTE TRIP FEATURE SECOND LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC FIRST LOCATION. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-425-4332 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com