The Circuit Breaker, cataloged under National Stock Number 5925-01-422-6653, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 19 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 3 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-422-6653 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 115.0 AC AND 28.0 DC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 2 THREADED HOLE(S) |
| Frequency in Hertz | 400.0 ALL LOCATIONS |
| Body Style | RECTANGULAR DIMENSIONAL ENVELOPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Pole Quantity | 1 |
| Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC AND 5.0 AMPERES DC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 3600.0 AC AND 3600.0 DC ALL LOCATIONS |
| Trip Delay Time in Seconds Per Rated Continuous Current | 7.000 MINIMUM AT 200 PCT AND 40.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| Inclosure Protection Type for Which Designed | GENERAL PURPOSE |
| Material | PLASTIC CASE |
| Trip Release Ambient Temp Rating | 40.0 CELSIUS NOMINAL ALL LOCATIONS DEGC |
| Terminal Type and Quantity | 2 THREADED STUD |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Trip Release Method | THERMAL ALL LOCATIONS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| MIL-PRF-83383/1 | 4/1 Identification reference U.S. Government activity |
| M83383/01-01 | 2/2 Government specification standardization U.S. Government activity |
| MIL-C-83383/1 | 5/9 Secondary reference U.S. Government activity |
| 6510-001-5 | C/1 Advisory reference — outside the item-of-supply concept Safran Electrical & Power Usa, Llc Dba Labinal Power Sysyems Use CAGE Code 81640 for Cataloging |
NSN 5925-01-422-6653 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
3 possible matches (shared part number, not a government interchangeability claim): 5925-01-423-4448, 5925-01-469-0694, 5925-01-592-2356. Verify interchangeability with system specifications before substitution.
Key specifications for 5925-01-422-6653: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 115.0 AC AND 28.0 DC ALL LOCATIONS; Mounting Facility Type and Quantity: 2 THREADED HOLE(S). 19 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.