PartsTable TECHNICAL DATA SHEET
NSN 5925-01-411-9726Government record, cited

Circuit Breaker5925-01-411-9726

NSN 5925-01-411-9726 · NIIN 014119726
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-411-9726 · 5925014119726 · NIIN 014119726 · 01-411-9726 · FSC 5925 Circuit Breakers · MIL-C-39019C · MIL-PRF-39019/1G · M39019/01-252S · MIL-PRF-39019/1
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.380 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC AND 50.0 DC SINGLE LOCATION
  • Frequency in Hertz: 400.0 SINGLE LOCATION
  • Body Style: SINGLE POLE TYPE
  • Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent: 200.0 SINGLE LOCATION
Identification
  • NSN: 5925-01-411-9726
  • NIIN: 014119726
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-411-9726, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 21 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-411-9726
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.380 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts240.0 AC AND 50.0 DC SINGLE LOCATION
Frequency in Hertz400.0 SINGLE LOCATION
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent200.0 SINGLE LOCATION
Special Test Features81349-M39019/01-252S
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width1.562 INCHES NOMINAL IN
Pole Quantity1
Maximum Continuous Load Current Rating Per Pole12.5 AMPERES AC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps300.0 AC AND 500.0 DC SINGLE LOCATION
Specification/standard Data81349-MIL-C-39019C GOVERNMENT SPECIFICATION
Body Length1.700 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT SINGLE LOCATION
Test Data Document81349-MIL-C-39019C SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Main Contact Tripping Mechanism TypeTRIP FREE
Trip Release MethodMAGNETIC SINGLE LOCATION
Center to Center Distance Between Terminals Parallel to Length0.906 INCHES NOMINAL IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MIL-C-39019C 5/9 Secondary reference
U.S. Government activity
MIL-PRF-39019/1G 5/9 Secondary reference
U.S. Government activity
M39019/01-252S 2/2 Government specification standardization
U.S. Government activity
MIL-PRF-39019/1 4/1 Identification reference
U.S. Government activity

Frequently Asked Questions

What is NSN 5925-01-411-9726?

NSN 5925-01-411-9726 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-411-9726?

Key specifications for 5925-01-411-9726: Bushing Length: 0.380 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC AND 50.0 DC SINGLE LOCATION. 21 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-411-9726 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.