PartsTable TECHNICAL DATA SHEET
NSN 5925-01-406-2865Government record, cited

Circuit Breaker5925-01-406-2865

NSN 5925-01-406-2865 · NIIN 014062865
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-406-2865 · 5925014062865 · NIIN 014062865 · 01-406-2865 · FSC 5925 Circuit Breakers · 62169-1 · 62169-1 · CE2-G3-AB0010-02B
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 460.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 4 THREADED HOLE(S)
  • Actuator Position Designation: AT EACH POLE
  • Frequency in Hertz: 60.0 ALL LOCATIONS
  • Center to Center Distance Between Terminals Parallel to Width: 1.028 INCHES NOMINAL IN
Identification
  • NSN: 5925-01-406-2865
  • NIIN: 014062865
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-406-2865, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-406-2865
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts460.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity4 THREADED HOLE(S)
Actuator Position DesignationAT EACH POLE
Frequency in Hertz60.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width1.028 INCHES NOMINAL IN
Body StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
External Actuator Linkage ArrangementONE, TWO, AND THREE LINKED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.750 INCHES NOMINAL IN
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width2.072 INCHES NOMINAL IN
Pole Quantity2
Mounting Surface to Terminal End Distance2.609 INCHES NOMINAL IN
Maximum Continuous Load Current Rating Per Pole10.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps1000.0 AC ALL LOCATIONS
Nominal Thread Size0.138 INCHES IN
Body Length5.800 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current25.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity2 TOGGLE
Distance Between Centerlines of Mounting Facilities Parallel to Body Width1.028 INCHES NOMINAL IN
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Terminal Type and Quantity2 COMPRESSION
Main Contact Tripping Mechanism TypeTRIP FREE
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC)
Boss Height0.219 INCHES NOMINAL IN
Trip Release MethodMAGNETIC ALL LOCATIONS
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
62169-1 3/9 Design control — primary reference
U.S. Government activity
62169-1 C/1 Advisory reference — outside the item-of-supply concept
Drs Environmental Systems Inc
CE2-G3-AB0010-02B 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div

Frequently Asked Questions

What is NSN 5925-01-406-2865?

NSN 5925-01-406-2865 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-406-2865?

Key specifications for 5925-01-406-2865: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 460.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-406-2865 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com