PartsTable TECHNICAL DATA SHEET
NSN 5925-01-372-0863Government record, cited

Circuit Breaker5925-01-372-0863

NSN 5925-01-372-0863 · NIIN 013720863 · Part number 179102-001
L3harris Technologies, Inc. Dba Harris Div L3harris Technologies Inc Dba Harris Corporation · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 66948
Government record, cited
NSN 5925-01-372-0863 — this item is cataloged by the U.S. Government under National Stock Number 5925-01-372-0863. Manufacturer of record part number: 179102-001.
Also searched as  5925-01-372-0863 · 5925013720863 · NIIN 013720863 · 01-372-0863 · FSC 5925 Circuit Breakers · CAGE 66948 · 179102-001 · AP-12-1RC-26205-2
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.380 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 50.0 DC FIRST LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC SECOND LOCATION
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING WITH PANEL SEAL
  • Actuator Position Designation: AT POLE ONE
Identification
  • NSN: 5925-01-372-0863
  • NIIN: 013720863
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 179102-001
  • Manufacturer: L3harris Technologies, Inc. Dba Harris Div L3harris Technologies Inc Dba Harris Corporation
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-372-0863, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is L3harris Technologies, Inc. Dba Harris Div L3harris Technologies Inc Dba Harris Corporation. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-372-0863
Primary Part Number179102-001
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerL3harris Technologies, Inc. Dba Harris Div L3harris Technologies Inc Dba Harris Corporation
StatusACTIVE
Bushing Length0.380 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts50.0 DC FIRST LOCATION
Operating Voltage Type and Rating Per Pole in Volts240.0 AC SECOND LOCATION
Mounting Facility Type and Quantity1 THREADED BUSHING WITH PANEL SEAL
Actuator Position DesignationAT POLE ONE
Frequency in Hertz60.0 SECOND LOCATION
Center to Center Distance Between Terminals Parallel to Width0.625 INCHES NOMINAL IN
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width1.281 INCHES MAXIMUM IN
Pole Quantity2
Mounting Surface to Terminal End Distance1.780 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole20.0 AMPERES DC FIRST LOCATION
Maximum Continuous Load Current Rating Per Pole8.0 AMPERES AC SECOND LOCATION
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps300.0 AC SECOND LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps500.0 DC FIRST LOCATION
Nominal Thread Size0.375 INCHES IN
Body Length1.562 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.060 MINIMUM AT 200 PCT AND 0.600 MAXIMUM AT 200 PCT FIRST LOCATION
Trip Delay Time in Seconds Per Rated Continuous Current0.200 MINIMUM AT 200 PCT AND 1.700 MAXIMUM AT 200 PCT SECOND LOCATION
Manual Actuator Type and Quantity1 TOGGLE
Actuator FunctionTRIP-RESET
Terminal Type and Quantity4 WIRE HOOK
Main Contact Tripping Mechanism TypeTRIP FREE
Thread Series DesignatorUNEF
Trip Release MethodMAGNETIC ALL LOCATIONS
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
179102-001 PRIMARY L3harris Technologies, Inc. Dba Harris Div L3harris Technologies Inc Dba Harris Corporation (USA)
Reference documents
ReferenceMeaning
AP-12-1RC-26205-2 5/2 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-372-0863?

NSN 5925-01-372-0863 is a Circuit Breaker, manufactured by L3harris Technologies, Inc. Dba Harris Div L3harris Technologies Inc Dba Harris Corporation, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-01-372-0863?

NSN 5925-01-372-0863 has 1 manufacturer part number on file: 179102-001 (L3harris Technologies, Inc. Dba Harris Div L3harris Technologies Inc Dba Harris Corporation).

What are the specifications of 179102-001?

Key specifications for 179102-001: Bushing Length: 0.380 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 50.0 DC FIRST LOCATION. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-372-0863 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.