The Circuit Breaker, cataloged under National Stock Number 5925-01-371-4505, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 8 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 2 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-371-4505 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Operating Voltage Type and Rating Per Pole in Volts | 500.0 AC ALL LOCATIONS |
| Frequency in Hertz | 400.0 ALL LOCATIONS |
| Circuit Protection Type | UNDERVOLTAGE ALL LOCATIONS |
| Supplementary Features | AQB-A250 W/SHUNT TRP |
| Pole Quantity | 3 |
| Maximum Continuous Load Current Rating Per Pole | 250.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | INSTANTANEOUS AND TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 10000.0 AC ALL LOCATIONS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 82E8008 | 3/2 Design control — primary reference U.S. Government activity |
| MIL-C-17361/6 | 4/1 Identification reference U.S. Government activity |
NSN 5925-01-371-4505 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
2 possible matches (shared part number, not a government interchangeability claim): 5925-01-371-4506, 5925-01-373-4856. Verify interchangeability with system specifications before substitution.
Key specifications for 5925-01-371-4505: Operating Voltage Type and Rating Per Pole in Volts: 500.0 AC ALL LOCATIONS; Frequency in Hertz: 400.0 ALL LOCATIONS; Circuit Protection Type: UNDERVOLTAGE ALL LOCATIONS; Supplementary Features: AQB-A250 W/SHUNT TRP. 8 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.