The Circuit Breaker, cataloged under National Stock Number 5925-01-370-3458, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Kft Fire Trainer Llc. Government technical data includes 20 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-370-3458 |
| Primary Part Number | QD1-B-34-615-1-A16-2C |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Kft Fire Trainer Llc |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 AC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 2 CLIP |
| Actuator Position Designation | AT POLE ONE |
| Frequency in Hertz | 60.0 SINGLE LOCATION |
| Body Style | RECTANGULAR DIMENSIONAL ENVELOPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 SINGLE LOCATION |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Pole Quantity | 1 |
| Maximum Continuous Load Current Rating Per Pole | 15.0 AMPERES AC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 3500.0 AC SINGLE LOCATION |
| Trip Delay Time in Seconds Per Rated Continuous Current | 3.500 MINIMUM AT 200 PCT AND 30.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 2 TAB, SOLDER LUG |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Trip Release Method | MAGNETIC SINGLE LOCATION |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| QD1-B-34-615-1-A16-2C PRIMARY | Kft Fire Trainer Llc (USA) |
| Reference | Meaning |
|---|---|
| 3A1-002-279 ITEM 002 | 5/9 Secondary reference Kft Fire Trainer Llc |
| TX1-P15-U00-BK2 | 5/9 Secondary reference Eaton Corp Heinemann Products Commercial Controls Div |
NSN 5925-01-370-3458 is a Circuit Breaker, manufactured by Kft Fire Trainer Llc, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-370-3458 has 1 manufacturer part number on file: QD1-B-34-615-1-A16-2C (Kft Fire Trainer Llc).
Key specifications for QD1-B-34-615-1-A16-2C: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 2 CLIP. 20 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.