The Circuit Breaker, cataloged under National Stock Number 5925-01-367-7922, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Eaton Corp Aerospace Commercial Controls Div. Government technical data includes 22 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-367-7922 |
| Primary Part Number | KD1-0.510F8609 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Eaton Corp Aerospace Commercial Controls Div |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 AC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 2 CLIP |
| Actuator Position Designation | AT POLE ONE |
| Frequency in Hertz | 50.0 OR 60.0 SINGLE LOCATION |
| Body Style | SINGLE POLE TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 SINGLE LOCATION |
| Overall Diameter | 0.796 INCHES NOMINAL IN |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Pole Quantity | 1 |
| Maximum Continuous Load Current Rating Per Pole | 0.500 MILLIAMPERES AC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1000.0 AC SINGLE LOCATION |
| Body Length | 1.406 INCHES NOMINAL IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 4.500 MINIMUM AT 200 PCT AND 18.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Manual Actuator Type and Quantity | 1 PUSH BUTTON |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 2 TAB, SOLDER LUG |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Trip Release Method | MAGNETIC SINGLE LOCATION |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| KD1-0.510F8609 | Eaton Corp Aerospace Commercial Controls Div (USA) |
| Reference | Meaning |
|---|---|
| KD1-0.510F8609 | 3/9 Design control — primary reference Eaton Corp Heinemann Products Commercial Controls Div |
NSN 5925-01-367-7922 is a Circuit Breaker, manufactured by Eaton Corp Aerospace Commercial Controls Div, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-367-7922 has 1 manufacturer part number on file: KD1-0.510F8609 (Eaton Corp Aerospace Commercial Controls Div).
Key specifications for KD1-0.510F8609: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC SINGLE LOCATION; Mounting Facility Type and Quantity: 2 CLIP. 22 specifications are documented in the U.S. Government catalog.