The Circuit Breaker, cataloged under National Stock Number 5925-01-363-6284, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Oakland Industries Ltd. Government technical data includes 23 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-363-6284 |
| Primary Part Number | 412-K14-LN2 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Oakland Industries Ltd |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 115.0 AC AND 28.0 DC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING |
| Actuator Position Designation | AT POLE ONE |
| Frequency in Hertz | 60.0 SINGLE LOCATION |
| Body Style | RECTANGULAR DIMENSIONAL ENVELOPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 SINGLE LOCATION |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Pole Quantity | 1 |
| Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC AND 5.0 AMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1500.0 AC AND 1500.0 DC SINGLE LOCATION |
| Nominal Thread Size | 0.164 INCHES IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 20.000 MINIMUM AT 200 PCT AND 70.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Thread Quantity Per Inch | 32 |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 2 TAB W/SCREW |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) |
| Trip Release Method | MAGNETIC SINGLE LOCATION |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 412-K14-LN2 PRIMARY | Oakland Industries Ltd (USA) |
| Reference | Meaning |
|---|---|
| 41-2-S14-LN2 | 5/9 Secondary reference Oakland Industries Ltd |
NSN 5925-01-363-6284 is a Circuit Breaker, manufactured by Oakland Industries Ltd, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-363-6284 has 1 manufacturer part number on file: 412-K14-LN2 (Oakland Industries Ltd).
Key specifications for 412-K14-LN2: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 115.0 AC AND 28.0 DC SINGLE LOCATION; Mounting Facility Type and Quantity: 1 THREADED BUSHING. 23 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.