The Circuit Breaker, cataloged under National Stock Number 5925-01-361-4273, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 7 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 3 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-361-4273 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Operating Voltage Type and Rating Per Pole in Volts | 50.0 DC SINGLE LOCATION |
| Pole Quantity | 1 |
| Maximum Continuous Load Current Rating Per Pole | 0.5 AMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 2000.0 DC SINGLE LOCATION |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.130 MINIMUM AT 200 PCT AND 1.600 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Trip Release Method | MAGNETIC SINGLE LOCATION |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| M55629/8-009 | 2/2 Government specification standardization U.S. Government activity |
| MIL-PRF-55629/8 | 4/1 Identification reference U.S. Government activity |
NSN 5925-01-361-4273 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
3 possible matches (shared part number, not a government interchangeability claim): 5925-01-370-6355, 5925-01-370-6356, 5925-01-370-6357. Verify interchangeability with system specifications before substitution.
Key specifications for 5925-01-361-4273: Operating Voltage Type and Rating Per Pole in Volts: 50.0 DC SINGLE LOCATION; Pole Quantity: 1; Maximum Continuous Load Current Rating Per Pole: 0.5 AMPERES DC SINGLE LOCATION; Trip Release Characteristic: TIME DELAY SINGLE LOCATION. 7 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.