The Circuit Breaker, cataloged under National Stock Number 5925-01-347-9838, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 16 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-347-9838 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Bushing Length | 0.115 INCHES MINIMUM AND 0.145 INCHES MAXIMUM IN |
| Reset Method | MANUAL |
| Operating Voltage Type and Rating Per Pole in Volts | 50.0 DC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 6 TERMINAL |
| Body Style | SINGLE POLE TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 150.0 SINGLE LOCATION |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM IN |
| Pole Quantity | 1 |
| Mounting Surface to Terminal End Distance | 2.232 INCHES NOMINAL IN |
| Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | INSTANTANEOUS SINGLE LOCATION |
| Body Length | 1.969 INCHES MINIMUM AND 2.031 INCHES MAXIMUM IN |
| Terminal Type and Quantity | 8 SCREW |
| Trip Release Method | MAGNETIC SINGLE LOCATION |
| Center to Center Distance Between Terminals Parallel to Length | 1.499 INCHES MINIMUM AND 1.561 INCHES MAXIMUM IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| M55629/20LR | 2/2 Government specification standardization U.S. Government activity |
| MIL-PRF-55629/20 | 4/1 Identification reference U.S. Government activity |
| MIL-C-55629/20 | 5/9 Secondary reference U.S. Government activity |
NSN 5925-01-347-9838 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-347-9838: Bushing Length: 0.115 INCHES MINIMUM AND 0.145 INCHES MAXIMUM IN; Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 50.0 DC SINGLE LOCATION; Mounting Facility Type and Quantity: 6 TERMINAL. 16 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.