PartsTable TECHNICAL DATA SHEET
NSN 5925-01-332-9927Government record, cited

Circuit Breaker5925-01-332-9927

NSN 5925-01-332-9927 · NIIN 013329927 · Part number 865528-1
Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 06481
Government record, cited
NSN 5925-01-332-9927 — this item is cataloged by the U.S. Government under National Stock Number 5925-01-332-9927. Manufacturer of record part number: 865528-1.
Also searched as  5925-01-332-9927 · 5925013329927 · NIIN 013329927 · 01-332-9927 · FSC 5925 Circuit Breakers · CAGE 06481 · 865528-1 · AP12-24241-1
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 28.0 DC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING WITH PANEL SEAL
  • Actuator Position Designation: BETWEEN POLE ONE AND TWO
  • Center to Center Distance Between Terminals Parallel to Width: 0.927 INCHES MINIMUM AND 0.947 INCHES MAXIMUM IN
Identification
  • NSN: 5925-01-332-9927
  • NIIN: 013329927
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 865528-1
  • Manufacturer: Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-332-9927, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-332-9927
Primary Part Number865528-1
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerNorthrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp
StatusACTIVE
Bushing Length0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts28.0 DC ALL LOCATIONS
Mounting Facility Type and Quantity1 THREADED BUSHING WITH PANEL SEAL
Actuator Position DesignationBETWEEN POLE ONE AND TWO
Center to Center Distance Between Terminals Parallel to Width0.927 INCHES MINIMUM AND 0.947 INCHES MAXIMUM IN
Nonturn Device Radius0.581 INCHES MINIMUM AND 0.701 INCHES MAXIMUM IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent115.0 ALL LOCATIONS
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width1.281 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity2
Mounting Surface to Terminal End Distance1.828 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole500.0 MILLIAMPERES DC SECOND LOCATION
Maximum Continuous Load Current Rating Per Pole7.5 AMPERES DC FIRST LOCATION
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps500.0 DC ALL LOCATIONS
Nominal Thread Size0.375 INCHES IN
Body Length1.562 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity1 TOGGLE
Inclosure Protection Type for Which DesignedVIBRATION RESISTANT AND SHOCKPROOF AND MOISTURE RESISTANT AND SALT SPRAY PROOF
Thread Quantity Per Inch32
Actuator FunctionTRIP-RESET
Terminal Type and Quantity4 WIRE HOOK
Special Handling FeatureMAGNETIC
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
865528-1 PRIMARY Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp (USA)
Reference documents
ReferenceMeaning
865528-1 3/9 Design control — primary reference
Litton Systems Inc. Div Navigation Systems Division
AP12-24241-1 5/2 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-332-9927?

NSN 5925-01-332-9927 is a Circuit Breaker, manufactured by Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-01-332-9927?

NSN 5925-01-332-9927 has 1 manufacturer part number on file: 865528-1 (Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp).

What are the specifications of 865528-1?

Key specifications for 865528-1: Bushing Length: 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 28.0 DC ALL LOCATIONS. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-332-9927 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com