PartsTable TECHNICAL DATA SHEET
NSN 5925-01-332-1035Government record, cited

Circuit Breaker5925-01-332-1035

NSN 5925-01-332-1035 · NIIN 013321035 · Part number 921102-27
Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 06481
Government record, cited
NSN 5925-01-332-1035 — this item is cataloged by the U.S. Government under National Stock Number 5925-01-332-1035. Manufacturer of record part number: 921102-27.
Also searched as  5925-01-332-1035 · 5925013321035 · NIIN 013321035 · 01-332-1035 · FSC 5925 Circuit Breakers · CAGE 06481 · 921102-27 · JC2S-Z29-1 · JC2-B3CB-A-P1-15-3-P2-5-3
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 65.0 DC SECOND LOCATION
  • Mounting Facility Type and Quantity: 4 THREADED HOLE(S)
  • Actuator Position Designation: AT EACH POLE
  • Center to Center Distance Between Terminals Parallel to Width: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM IN
  • Fragility Factor: MODERATELY RUGGED
Identification
  • NSN: 5925-01-332-1035
  • NIIN: 013321035
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 921102-27
  • Manufacturer: Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-332-1035, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-332-1035
Primary Part Number921102-27
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerNorthrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts65.0 DC SECOND LOCATION
Mounting Facility Type and Quantity4 THREADED HOLE(S)
Actuator Position DesignationAT EACH POLE
Center to Center Distance Between Terminals Parallel to Width0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
External Actuator Linkage ArrangementONE AND TWO LINKED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length1.629 INCHES MINIMUM AND 1.691 INCHES MAXIMUM IN
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width1.119 INCHES MINIMUM AND 1.181 INCHES MAXIMUM IN
Body Height2.229 INCHES MINIMUM AND 2.291 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity2
Maximum Continuous Load Current Rating Per Pole15.0 AMPERES DC FIRST LOCATION
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps2000.0 DC ALL LOCATIONS
Nominal Thread Size0.138 INCHES IN
Body Length2.606 INCHES MINIMUM AND 2.668 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.900 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity2 TOGGLE
Distance Between Centerlines of Mounting Facilities Parallel to Body Width0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM IN
Inclosure Protection Type for Which DesignedDUSTPROOF AND FUNGUS PROOF
Thread Quantity Per Inch32
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Terminal Type and Quantity4 TAB, SOLDER LUG
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
921102-27 PRIMARY Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp (USA)
Reference documents
ReferenceMeaning
JC2S-Z29-1 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
JC2-B3CB-A-P1-15-3-P2-5-3 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-332-1035?

NSN 5925-01-332-1035 is a Circuit Breaker, manufactured by Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-01-332-1035?

NSN 5925-01-332-1035 has 1 manufacturer part number on file: 921102-27 (Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp).

What are the specifications of 921102-27?

Key specifications for 921102-27: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 65.0 DC SECOND LOCATION; Mounting Facility Type and Quantity: 4 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-332-1035 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com