The Circuit Breaker, cataloged under National Stock Number 5925-01-331-6300, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-331-6300 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Operating Voltage Type and Rating Per Pole in Volts | 600.0 AC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 4 UNTHREADED HOLE(S) |
| Actuator Position Designation | AT POLE TWO |
| Frequency in Hertz | 60.0 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 1.375 INCHES NOMINAL IN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 4.282 INCHES NOMINAL IN |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 4.125 INCHES NOMINAL IN |
| Body Height | 3.375 INCHES NOMINAL IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Unthreaded Mounting Hole Diameter | 0.164 INCHES NOMINAL IN |
| Pole Quantity | 3 |
| Maximum Continuous Load Current Rating Per Pole | 35.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 18000.0 AC ALL LOCATIONS |
| Body Length | 6.000 INCHES NOMINAL IN |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 1.375 INCHES NOMINAL IN |
| Inclosure Protection Type for Which Designed | DUSTPROOF |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Trip Release Ambient Temp Rating | 40.0 CELSIUS NOMINAL ALL LOCATIONS DEGC |
| Terminal Type and Quantity | 6 COMPRESSION |
| Special Handling Feature | MAGNETIC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| FD3035L | 3/2 Design control — primary reference U.S. Government activity |
| FD3035 | C/1 Advisory reference — outside the item-of-supply concept Westinghouse Electric Corp |
NSN 5925-01-331-6300 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
1 possible match (shared part number, not a government interchangeability claim): 4710-01-554-4373. Verify interchangeability with system specifications before substitution.
Key specifications for 5925-01-331-6300: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 600.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S); Actuator Position Designation: AT POLE TWO. 29 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.