The Circuit Breaker, cataloged under National Stock Number 5925-01-322-7930, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-322-7930 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 AC AND 65.0 DC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 4 CLIP |
| Actuator Position Designation | BETWEEN POLE ONE AND TWO |
| Switch Terminal Type | TAB, SOLDER LUG |
| Frequency in Hertz | 50.0 OR 60.0 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 0.615 INCHES MINIMUM AND 0.635 INCHES MAXIMUM IN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| Switch Voltage Rating and Type in Volts | 120.0 AC AND 32.0 DC |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Switch Location and Position Designation | INTERNAL AT POLE ONE |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 1.384 INCHES MINIMUM AND 1.404 INCHES MAXIMUM IN |
| Body Height | 1.810 INCHES MINIMUM AND 1.870 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 2 |
| Maximum Continuous Load Current Rating Per Pole | 2.0 AMPERES AC AND 2.0 AMPERES DC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1000.0 AC AND 1000.0 DC ALL LOCATIONS |
| Body Length | 1.550 INCHES MINIMUM AND 1.570 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 1.000 MINIMUM AT 200 PCT AND 15.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Switch Current Rating and Type in Amps | 3.0 AC AND 1.5 DC |
| Inclosure Protection Type for Which Designed | DUSTPROOF AND FUNGUS PROOF |
| Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| R25-2-2.00A-B121EV | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-322-7930 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-322-7930: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC AND 65.0 DC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 CLIP. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.