PartsTable TECHNICAL DATA SHEET
NSN 5925-01-318-9443Government record, cited

Circuit Breaker5925-01-318-9443

NSN 5925-01-318-9443 · NIIN 013189443
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-318-9443 · 5925013189443 · NIIN 013189443 · 01-318-9443 · FSC 5925 Circuit Breakers · NJL631400MT0 · NJL632400MTO-AL 1 · NJL631400MTO-ASF-1
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Operating Voltage Type and Rating Per Pole in Volts: 600.0 AC AND 250.0 DC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 4 THREADED STUD(S)
  • Actuator Position Designation: AT POLE TWO
  • Switch Terminal Type: WIRE LEAD
  • Frequency in Hertz: 60.0 ALL LOCATIONS
  • Center to Center Distance Between Terminals Parallel to Width: 1.880 INCHES NOMINAL IN
Identification
  • NSN: 5925-01-318-9443
  • NIIN: 013189443
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-318-9443, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-318-9443
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Operating Voltage Type and Rating Per Pole in Volts600.0 AC AND 250.0 DC ALL LOCATIONS
Mounting Facility Type and Quantity4 THREADED STUD(S)
Actuator Position DesignationAT POLE TWO
Switch Terminal TypeWIRE LEAD
Frequency in Hertz60.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width1.880 INCHES NOMINAL IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Switch Voltage Rating and Type in Volts250.0 AC
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
Adjustable Trip Setting Current Range Per Pole in Amps+3000.0 TO 4800.0 AC ALL LOCATIONS
Distance Between Centerlines of Mounting Facilities Parallel to Body Length7.250 INCHES NOMINAL IN
Arc Quenching MethodMAGNETIC BLOWOUT
Switch Location and Position DesignationINTERNAL AT POLE ONE
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width8.250 INCHES NOMINAL IN
Body Height4.080 INCHES NOMINAL IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity3
Maximum Continuous Load Current Rating Per Pole400.0 AMPERES AC AND 400.0 AMPERES DC ALL LOCATIONS
Features ProvidedADJUSTABLE TRIP RELEASE
Trip Release CharacteristicINSTANTANEOUS ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps150000.0 AC AND 220000.0 DC ALL LOCATIONS
Nominal Thread Size0.500 INCHES IN
Body Length10.120 INCHES NOMINAL IN
Manual Actuator Type and Quantity1 TOGGLE
Switch Current Rating and Type in Amps5.0 AC
Distance Between Centerlines of Mounting Facilities Parallel to Body Width1.220 INCHES NOMINAL IN
Inclosure Protection Type for Which DesignedMOISTURE PROOF AND FUNGUS PROOF
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
NJL631400MT0 C/1 Advisory reference — outside the item-of-supply concept
Challenger Electrical Equipment Corp
NJL632400MTO-AL 1 3/9 Design control — primary reference
American Circuit Breaker Corp
NJL631400MTO-ASF-1 C/1 Advisory reference — outside the item-of-supply concept
Challenger Electrical Equipment Corp
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-318-9443?

NSN 5925-01-318-9443 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-318-9443?

Key specifications for 5925-01-318-9443: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 600.0 AC AND 250.0 DC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 THREADED STUD(S); Actuator Position Designation: AT POLE TWO. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-318-9443 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com