The Circuit Breaker, cataloged under National Stock Number 5925-01-313-0960, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Sae International Dba Sae International. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-313-0960 |
| Primary Part Number | MS25361-50V |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Sae International Dba Sae International |
| Status | ACTIVE |
| Bushing Length | 0.454 INCHES MINIMUM AND 0.516 INCHES MAXIMUM IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 200.0 AC AND 28.0 DC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 2 THREADED HOLE(S) |
| Actuator Position Designation | AT POLE ONE |
| Frequency in Hertz | 60.0 SINGLE LOCATION |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | SINGLE POLE TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 150.0 SINGLE LOCATION |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 1.807 INCHES MINIMUM AND 1.817 INCHES MAXIMUM IN |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 0.750 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 1 |
| Mounting Surface to Terminal End Distance | 2.250 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC AND 50.0 AMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 3500.0 AC AND 6000.0 DC SINGLE LOCATION |
| Nominal Thread Size | 0.138 INCHES IN |
| Specification/standard Data | 96906-MS25361 GOVERNMENT STANDARD |
| Body Length | 2.189 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 15.000 MINIMUM AT 200 PCT AND 65.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Manual Actuator Type and Quantity | 1 PUSH-PULL |
| Inclosure Protection Type for Which Designed | VIBRATIONPROOF |
| Test Data Document | 81349-MIL-C-5809 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| Thread Quantity Per Inch | 32 |
| Actuator Function | TRIP-RESET |
| Trip Release Ambient Temp Rating | 40.0 CELSIUS NOMINAL SINGLE LOCATION DEGC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| MS25361-50V PRIMARY | Sae International Dba Sae International (USA) |
| Reference | Meaning |
|---|---|
| MS25361-50V | 5/9 Secondary reference U.S. Government activity |
| MIL-C-5809 | 5/9 Secondary reference U.S. Government activity |
| SAE-AS58091 | 3/1 Design control — primary reference Sae International Dba Sae International |
NSN 5925-01-313-0960 is a Circuit Breaker, manufactured by Sae International Dba Sae International, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-313-0960 has 1 manufacturer part number on file: MS25361-50V (Sae International Dba Sae International).
Key specifications for MS25361-50V: Bushing Length: 0.454 INCHES MINIMUM AND 0.516 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 200.0 AC AND 28.0 DC SINGLE LOCATION. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.