Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING WITH PANEL SEAL
  • Actuator Position Designation: AT POLE TWO
  • Switch Terminal Type: TAB, SOLDER LUG
Identification
  • NSN: 5925-01-311-9924
  • NIIN: 013119924
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-311-9924, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-311-9924
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts240.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity1 THREADED BUSHING WITH PANEL SEAL
Actuator Position DesignationAT POLE TWO
Switch Terminal TypeTAB, SOLDER LUG
Frequency in Hertz400.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM IN
Nonturn Device Radius0.641 INCHES MINIMUM AND 0.671 INCHES MAXIMUM IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Switch Voltage Rating and Type in Volts250.0 AC AND 50.0 DC
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent150.0 ALL LOCATIONS
Arc Quenching MethodMAGNETIC BLOWOUT
Switch Location and Position DesignationINTERNAL AT POLE ONE
Nonturn Device Length0.115 INCHES MINIMUM AND 0.145 INCHES MAXIMUM IN
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width2.265 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity3
Mounting Surface to Terminal End Distance2.232 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole20.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps1000.0 AC ALL LOCATIONS
Nominal Thread Size0.500 INCHES IN
Specification/standard Data81349-MIL-C-55629/22 GOVERNMENT SPECIFICATION
Body Length1.969 INCHES MINIMUM AND 2.031 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current2.100 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity1 TOGGLE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5925-01-496-7488APGN-666-1-42-203 POSSIBLE MATCH
CIRCUIT BREAKER
Possible match (shared part number)Sensata Technologies Maryland, Inc
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
APGN-666-1-42-203 C/1 Advisory reference — outside the item-of-supply concept
U.S. Government activity
MIL-C-55629/22 5/9 Secondary reference
U.S. Government activity
MIL-PRF-55629/22 4/1 Identification reference
U.S. Government activity
M55629/22SPSPSP 2/2 Government specification standardization
U.S. Government activity
Related Parts
5925-01-496-7488POSSIBLE MATCH
CIRCUIT BREAKER
APGN-666-1-42-203

Frequently Asked Questions

What is NSN 5925-01-311-9924?

NSN 5925-01-311-9924 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What NSN replaces 5925-01-311-9924?

1 possible match (shared part number, not a government interchangeability claim): 5925-01-496-7488. Verify interchangeability with system specifications before substitution.

What are the specifications of 5925-01-311-9924?

Key specifications for 5925-01-311-9924: Bushing Length: 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-311-9924 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com