PartsTable TECHNICAL DATA SHEET
NSN 5925-01-311-3087Government record, cited

Circuit Breaker5925-01-311-3087

NSN 5925-01-311-3087 · NIIN 013113087
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-311-3087 · 5925013113087 · NIIN 013113087 · 01-311-3087 · FSC 5925 Circuit Breakers
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Operating Voltage Type and Rating Per Pole in Volts: 600.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S)
  • Actuator Position Designation: AT POLE TWO
  • Frequency in Hertz: 50.0 OR 60.0 ALL LOCATIONS
  • Unpackaged Unit Weight: 4.750 POUNDS NOMINAL LBS
  • Center to Center Distance Between Terminals Parallel to Width: 1.375 INCHES NOMINAL IN
Identification
  • NSN: 5925-01-311-3087
  • NIIN: 013113087
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-311-3087, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-311-3087
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Operating Voltage Type and Rating Per Pole in Volts600.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity4 UNTHREADED HOLE(S)
Actuator Position DesignationAT POLE TWO
Frequency in Hertz50.0 OR 60.0 ALL LOCATIONS
Unpackaged Unit Weight4.750 POUNDS NOMINAL LBS
Center to Center Distance Between Terminals Parallel to Width1.375 INCHES NOMINAL IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
Distance Between Centerlines of Mounting Facilities Parallel to Body Length4.282 INCHES NOMINAL IN
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width4.125 INCHES NOMINAL IN
Body Height3.188 INCHES NOMINAL IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Unthreaded Mounting Hole Diameter0.164 INCHES NOMINAL IN
Pole Quantity3
Maximum Continuous Load Current Rating Per Pole60.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicINSTANTANEOUS ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps18000.0 AC ALL LOCATIONS
Body Length6.000 INCHES NOMINAL IN
Manual Actuator Type and Quantity1 TOGGLE
Distance Between Centerlines of Mounting Facilities Parallel to Body Width1.375 INCHES NOMINAL IN
Inclosure Protection Type for Which DesignedDUSTPROOF
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Trip Release Ambient Temp Rating40.0 CELSIUS NOMINAL ALL LOCATIONS DEGC
Terminal Type and Quantity6 COMPRESSION
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
4710-01-572-1989FD3060 POSSIBLE MATCH
PIPE ASSEMBLY,METAL
Possible match (shared part number)Critical Solutions International, Llc
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
FD3060 3/2 Design control — primary reference
U.S. Government activity
Related Parts
4710-01-572-1989POSSIBLE MATCH
PIPE ASSEMBLY,METAL
FD3060

Frequently Asked Questions

What is NSN 5925-01-311-3087?

NSN 5925-01-311-3087 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What NSN replaces 5925-01-311-3087?

1 possible match (shared part number, not a government interchangeability claim): 4710-01-572-1989. Verify interchangeability with system specifications before substitution.

What are the specifications of 5925-01-311-3087?

Key specifications for 5925-01-311-3087: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 600.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S); Actuator Position Designation: AT POLE TWO. 29 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-311-3087 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com