PartsTable TECHNICAL DATA SHEET
NSN 5925-01-306-2719Government record, cited

Circuit Breaker5925-01-306-2719

NSN 5925-01-306-2719 · NIIN 013062719
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-306-2719 · 5925013062719 · NIIN 013062719 · 01-306-2719 · FSC 5925 Circuit Breakers · CD6B16B3 · 716018
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 250.0 DC ALL LOCATIONS
  • Fragility Factor: MODERATELY RUGGED
  • Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent: 125.0 ALL LOCATIONS
  • Circuit Protection Type: OVERCURRENT ALL LOCATIONS
  • Storage Type: GENERAL PURPOSE WAREHOUSE
Identification
  • NSN: 5925-01-306-2719
  • NIIN: 013062719
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-306-2719, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 16 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-306-2719
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts250.0 DC ALL LOCATIONS
Fragility FactorMODERATELY RUGGED
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity6
Maximum Continuous Load Current Rating Per Pole50.0 AMPERES DC ALL LOCATIONS
Trip Release CharacteristicINSTANTANEOUS ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps1000.0 DC ALL LOCATIONS
Inclosure Protection Type for Which DesignedGENERAL PURPOSE
MaterialPLASTIC CASE
Special Handling FeatureMAGNETIC
Main Contact Tripping Mechanism TypeTRIP FREE
Trip Release MethodMAGNETIC ALL LOCATIONS
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
3950-01-601-5868716018-1 POSSIBLE MATCH
FRAME,HOIST
Possible match (shared part number)Drs Sustainment Systems Inc
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
CD6B16B3 C/1 Advisory reference — outside the item-of-supply concept
Eaton Corp Heinemann Products Commercial Controls Div
716018 3/9 Design control — primary reference
Pacific Power Source
Related Parts
3950-01-601-5868POSSIBLE MATCH
FRAME,HOIST
716018-1

Frequently Asked Questions

What is NSN 5925-01-306-2719?

NSN 5925-01-306-2719 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What NSN replaces 5925-01-306-2719?

1 possible match (shared part number, not a government interchangeability claim): 3950-01-601-5868. Verify interchangeability with system specifications before substitution.

What are the specifications of 5925-01-306-2719?

Key specifications for 5925-01-306-2719: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 250.0 DC ALL LOCATIONS; Fragility Factor: MODERATELY RUGGED. 16 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-306-2719 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com