The Circuit Breaker, cataloged under National Stock Number 5925-01-302-8952, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Thales Sa. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-302-8952 |
| Primary Part Number | 91567649 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Thales Sa |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 65.0 DC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 6 THREADED HOLE(S) |
| Actuator Position Designation | AT EACH POLE |
| Switch Terminal Type | QUICK DISCONNECT, MALE |
| Unpackaged Unit Weight | 11.100 OUNCES NOMINAL OZ |
| Center to Center Distance Between Terminals Parallel to Width | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM IN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Switch Voltage Rating and Type in Volts | 250.0 AC AND 50.0 DC |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 115.0 ALL LOCATIONS |
| External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM IN |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Switch Location and Position Designation | INTERNAL AT POLE ONE |
| Thread Pitch in Millimeters | 0.50 |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 2.265 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 3 |
| Mounting Surface to Terminal End Distance | 2.491 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 50.0 MILLIAMPERES DC ALL LOCATIONS |
| Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 2000.0 DC ALL LOCATIONS |
| Nominal Thread Size | 3.0 MILLIMETERS MM |
| Body Length | 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM IN |
| Manual Actuator Type and Quantity | 3 TOGGLE |
| Switch Current Rating and Type in Amps | 10.0 AC AND 3.0 DC |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 91567649 | Thales Sa (FRA) |
| Reference | Meaning |
|---|---|
| APL-111-1REC2-59-051-MA | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-302-8952 is a Circuit Breaker, manufactured by Thales Sa, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-302-8952 has 1 manufacturer part number on file: 91567649 (Thales Sa).
Key specifications for 91567649: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 65.0 DC ALL LOCATIONS; Mounting Facility Type and Quantity: 6 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.