The Circuit Breaker, cataloged under National Stock Number 5925-01-296-8293, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Thales Sa. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-296-8293 |
| Primary Part Number | 91460044 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Thales Sa |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 AC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 4 THREADED HOLE(S) |
| Actuator Position Designation | AT EACH POLE |
| Switch Terminal Type | QUICK DISCONNECT, MALE |
| Frequency in Hertz | 400.0 ALL LOCATIONS |
| Unpackaged Unit Weight | 7.400 OUNCES NOMINAL OZ |
| Center to Center Distance Between Terminals Parallel to Width | 0.750 INCHES NOMINAL IN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Switch Voltage Rating and Type in Volts | 250.0 AC AND 50.0 DC |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 115.0 ALL LOCATIONS |
| External Actuator Linkage Arrangement | ONE AND TWO LINKED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM IN |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Switch Location and Position Designation | INTERNAL AT POLE ONE |
| Thread Pitch in Millimeters | 0.50 |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 1.500 INCHES MAXIMUM IN |
| Pole Quantity | 2 |
| Mounting Surface to Terminal End Distance | 2.475 INCHES NOMINAL IN |
| Maximum Continuous Load Current Rating Per Pole | 500.0 MILLIAMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 5000.0 AC ALL LOCATIONS |
| Nominal Thread Size | 3.0 MILLIMETERS MM |
| Body Length | 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT AND 22.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 2 TOGGLE |
| Switch Current Rating and Type in Amps | 10.0 AC AND 3.0 DC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 91460044 | Thales Sa (FRA) |
| Reference | Meaning |
|---|---|
| APL-11-1REC2-42F-501-MA | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-296-8293 is a Circuit Breaker, manufactured by Thales Sa, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-296-8293 has 1 manufacturer part number on file: 91460044 (Thales Sa).
Key specifications for 91460044: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.