The Circuit Breaker, cataloged under National Stock Number 5925-01-293-9115, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-293-9115 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Mounting Facility Type and Quantity | 6 THREADED HOLE(S) |
| Actuator Position Designation | AT EACH POLE |
| Unpackaged Unit Weight | 2.000 POUNDS NOMINAL LBS |
| Center to Center Distance Between Terminals Parallel to Width | 1.026 INCHES NOMINAL IN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.750 INCHES NOMINAL IN |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Body Width | 4.750 INCHES NOMINAL IN |
| Body Height | 2.599 INCHES MINIMUM AND 2.619 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 3 |
| Nominal Thread Size | 0.138 INCHES IN |
| Body Length | 5.800 INCHES NOMINAL IN |
| Manual Actuator Type and Quantity | 3 TOGGLE |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 1.026 INCHES NOMINAL IN |
| Inclosure Protection Type for Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT |
| Thread Quantity Per Inch | 32 |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 6 THREADED STUD |
| Special Handling Feature | MAGNETIC |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) |
| Boss Height | 0.219 INCHES NOMINAL IN |
| Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Length | 3.547 INCHES NOMINAL IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| CD3-Z343-1 | 3/2 Design control — primary reference U.S. Government activity |
| CD3-Z343-1 | 3/9 Design control — primary reference Eaton Corp Heinemann Products Commercial Controls Div |
| 5265749 | C/1 Advisory reference — outside the item-of-supply concept Naval Sea Systems Command |
NSN 5925-01-293-9115 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-293-9115: Reset Method: MANUAL; Mounting Facility Type and Quantity: 6 THREADED HOLE(S); Actuator Position Designation: AT EACH POLE; Unpackaged Unit Weight: 2.000 POUNDS NOMINAL LBS. 29 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.