The Circuit Breaker, cataloged under National Stock Number 5925-01-293-5984, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Naval Sea Systems Command. Government technical data includes 29 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-293-5984 |
| Primary Part Number | 6097935-001 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Naval Sea Systems Command |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Operating Voltage Type and Rating Per Pole in Volts | 500.0 AC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 6 THREADED HOLE(S) |
| Actuator Position Designation | AT POLE TWO |
| Frequency in Hertz | 60.0 ALL LOCATIONS |
| Unpackaged Unit Weight | 2.750 POUNDS NOMINAL LBS |
| Center to Center Distance Between Terminals Parallel to Width | 1.375 INCHES NOMINAL IN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| Adjustable Trip Setting Current Range Per Pole in Amps | +600.0 TO 700.0 AC ALL LOCATIONS |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 3.313 INCHES NOMINAL IN |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 4.125 INCHES NOMINAL IN |
| Body Height | 4.094 INCHES NOMINAL IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Unthreaded Mounting Hole Diameter | 0.196 INCHES NOMINAL IN |
| Pole Quantity | 3 |
| Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC ALL LOCATIONS |
| Features Provided | ADJUSTABLE TRIP RELEASE |
| Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 15000.0 AC ALL LOCATIONS |
| Nominal Thread Size | 0.190 INCHES IN |
| Body Length | 6.500 INCHES NOMINAL IN |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 3.688 INCHES NOMINAL IN |
| Inclosure Protection Type for Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT |
| Thread Quantity Per Inch | 32 |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 6097935-001 | Naval Sea Systems Command (USA) |
| Reference | Meaning |
|---|---|
| 5682D24G22 W/315C364G03 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-293-5984 is a Circuit Breaker, manufactured by Naval Sea Systems Command, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-293-5984 has 1 manufacturer part number on file: 6097935-001 (Naval Sea Systems Command).
Key specifications for 6097935-001: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 500.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 6 THREADED HOLE(S); Actuator Position Designation: AT POLE TWO. 29 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.