The Circuit Breaker, cataloged under National Stock Number 5925-01-288-4245, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier. Government technical data includes 24 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-288-4245 |
| Primary Part Number | 247AS-C2847-002 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 AC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 4 CLIP |
| Actuator Position Designation | AT POLE TWO |
| Frequency in Hertz | 400.0 ALL LOCATIONS |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | RECTANGULAR DIMENSIONAL ENVELOPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 3 |
| Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1000.0 AC ALL LOCATIONS |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.045 MINIMUM AT 200 PCT AND 1.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 1 PUSH BUTTON |
| Inclosure Protection Type for Which Designed | DUSTPROOF |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 6 TAB, SOLDER LUG |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Trip Release Method | MAGNETIC ALL LOCATIONS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 247AS-C2847-002 PRIMARY | Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier (USA) |
| Reference | Meaning |
|---|---|
| 230-111-1-41-502-1-1 | 5/2 Secondary reference U.S. Government activity |
| 203-111-6313-2 | 5/9 Secondary reference U.S. Government activity |
NSN 5925-01-288-4245 is a Circuit Breaker, manufactured by Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-288-4245 has 1 manufacturer part number on file: 247AS-C2847-002 (Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier).
Key specifications for 247AS-C2847-002: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 CLIP. 24 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.