PartsTable TECHNICAL DATA SHEET
NSN 5925-01-288-4143Government record, cited

Circuit Breaker5925-01-288-4143

NSN 5925-01-288-4143 · NIIN 012884143 · Part number 1324AS153
Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 30003
Government record, cited
NSN 5925-01-288-4143 — this item is cataloged by the U.S. Government under National Stock Number 5925-01-288-4143. Manufacturer of record part number: 1324AS153.
Also searched as  5925-01-288-4143 · 5925012884143 · NIIN 012884143 · 01-288-4143 · FSC 5925 Circuit Breakers · CAGE 30003 · 1324AS153 · AP13-21419-1
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP FIRST LOCATION
  • Internal Trip Release Configuration: SHUNT TRIP SECOND LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC AND 50.0 DC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING WITH PANEL SEAL
  • Actuator Position Designation: AT POLE TWO
Identification
  • NSN: 5925-01-288-4143
  • NIIN: 012884143
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 1324AS153
  • Manufacturer: Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-288-4143, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-288-4143
Primary Part Number1324AS153
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerNaval Air Systems Command Managed Original Design Activity Not Material/parts Supplier
StatusACTIVE
Bushing Length0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP FIRST LOCATION
Internal Trip Release ConfigurationSHUNT TRIP SECOND LOCATION
Operating Voltage Type and Rating Per Pole in Volts240.0 AC AND 50.0 DC ALL LOCATIONS
Mounting Facility Type and Quantity1 THREADED BUSHING WITH PANEL SEAL
Actuator Position DesignationAT POLE TWO
Frequency in Hertz60.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent115.0 ALL LOCATIONS
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width1.281 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity2
Mounting Surface to Terminal End Distance1.828 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole250.0 MILLIAMPERES AC AND 250.0 MILLIAMPERES DC SECOND LOCATION
Maximum Continuous Load Current Rating Per Pole4.0 AMPERES AC AND 4.0 AMPERES DC FIRST LOCATION
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps300.0 AC AND 500.0 DC ALL LOCATIONS
Nominal Thread Size0.375 INCHES IN
Body Length1.552 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity1 TOGGLE
Inclosure Protection Type for Which DesignedHERMETICALLY SEALED
Thread Quantity Per Inch32
Actuator FunctionTRIP-RESET
Terminal Type and Quantity5 WIRE HOOK
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
1324AS153 PRIMARY Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier (USA)
Reference documents
ReferenceMeaning
1324AS153 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
AP13-21419-1 5/2 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-288-4143?

NSN 5925-01-288-4143 is a Circuit Breaker, manufactured by Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-01-288-4143?

NSN 5925-01-288-4143 has 1 manufacturer part number on file: 1324AS153 (Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier).

What are the specifications of 1324AS153?

Key specifications for 1324AS153: Bushing Length: 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP FIRST LOCATION; Internal Trip Release Configuration: SHUNT TRIP SECOND LOCATION. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-288-4143 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com