PartsTable TECHNICAL DATA SHEET
NSN 5925-01-287-4283Government record, cited

Circuit Breaker5925-01-287-4283

NSN 5925-01-287-4283 · NIIN 012874283
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-287-4283 · 5925012874283 · NIIN 012874283 · 01-287-4283 · FSC 5925 Circuit Breakers · AM4-A3A3A3A6-A-50-2 · 11426-90003 · UPL5111-22195-1
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SECOND LOCATION
  • Internal Trip Release Configuration: SERIES TRIP FIRST LOCATION
  • Internal Trip Release Configuration: SERIES TRIP THIRD LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC SECOND LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC FIRST LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC THIRD LOCATION
Identification
  • NSN: 5925-01-287-4283
  • NIIN: 012874283
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-287-4283, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-287-4283
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SECOND LOCATION
Internal Trip Release ConfigurationSERIES TRIP FIRST LOCATION
Internal Trip Release ConfigurationSERIES TRIP THIRD LOCATION
Operating Voltage Type and Rating Per Pole in Volts250.0 AC SECOND LOCATION
Operating Voltage Type and Rating Per Pole in Volts250.0 AC FIRST LOCATION
Operating Voltage Type and Rating Per Pole in Volts250.0 AC THIRD LOCATION
Mounting Facility Type and Quantity8 THREADED HOLE(S)
Actuator Position DesignationAT EACH POLE
Switch Terminal TypeTHREADED STUD
Frequency in Hertz60.0 THIRD LOCATION
Frequency in Hertz60.0 FIRST LOCATION
Frequency in Hertz60.0 SECOND LOCATION
Frequency in Hertz50.0 OR 60.0 FOURTH LOCATION
Unpackaged Unit Weight9.500 OUNCES NOMINAL OZ
Center to Center Distance Between Terminals Parallel to Width0.722 INCHES MINIMUM AND 0.782 INCHES MAXIMUM IN
Body StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
Switch Voltage Rating and Type in Volts250.0 AC
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 FIRST LOCATION
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 SECOND LOCATION
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 THIRD LOCATION
External Actuator Linkage ArrangementONE, TWO, THREE, AND FOUR LINKED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.030 INCHES MINIMUM AND 2.094 INCHES MAXIMUM IN
Switch Location and Position DesignationEXTERNAL AT POLE FOUR
Circuit Protection TypeOVERCURRENT FIRST LOCATION
Circuit Protection TypeOVERCURRENT THIRD LOCATION
Circuit Protection TypeOVERCURRENT SECOND LOCATION
Body Width2.968 INCHES MINIMUM AND 3.032 INCHES MAXIMUM IN
Pole Quantity4
Mounting Surface to Terminal End Distance2.688 INCHES MINIMUM AND 2.752 INCHES MAXIMUM IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
AM4-A3A3A3A6-A-50-2 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
11426-90003 3/2 Design control — primary reference
U.S. Government activity
UPL5111-22195-1 5/2 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-287-4283?

NSN 5925-01-287-4283 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-287-4283?

Key specifications for 5925-01-287-4283: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SECOND LOCATION; Internal Trip Release Configuration: SERIES TRIP FIRST LOCATION; Internal Trip Release Configuration: SERIES TRIP THIRD LOCATION. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-287-4283 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com